    Shear Resistance of Gypsum-Sheathed Light-Gauge Steel Stud Walls

    Source: Journal of Structural Engineering:;1996:;Volume ( 122 ):;issue: 004
    Author:
    Reynaud Serrette
    ,
    Kehinde Ogunfunmi
    DOI: 10.1061/(ASCE)0733-9445(1996)122:4(383)
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents detailed results on the shear behavior of 2.44 m by 2.44 m light-gauge steel stud walls for three different shear resisting systems: framed walls with 20 gauge flat strap X-bracing on the face—type A; framed walls with 12.5 mm (1/2 in.) single-ply gypsum wallboard on the back and 12.5 mm (1/2 in.) single-ply gypsum sheathing board on the face—type B; and framed walls with 12.5 mm (1/2 in.) single-ply gypsum wallboard on the back, 12.5 mm (1/2 in.) gypsum sheathing board on the face, and 20 gauge flat strap X-bracing on face—type C. The steel framing used in these tests is typical of framing used in residential construction. The behavior of the type A walls was governed by the yield strength of the straps with practically no resistance provided by flexure in the studs. In the type B and type C tests, the measured maximum load was controlled by the breaking of the wallboard along its edges. The failure mechanism was initiated by a rotation of the screws at the edges. This was followed by the partial pull-through of the screws at the edges of the gypsum board and simultaneous breaking of the board at the edges. Each 1.22 m by 2.44 m (4 ft by 8 ft) gypsum panel was observed to behave independently during loading. A comparison of the results from the type B and type C tests showed that the use of 50.8 mm, 20 gauge tension bracing prevented cracking of the boards at the perimeter, reduced the lateral displacement, and increased the maximum load capacity of the wall by as much as 28%.
    • Download: (1.299Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Shear Resistance of Gypsum-Sheathed Light-Gauge Steel Stud Walls

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/32436
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorReynaud Serrette
    contributor authorKehinde Ogunfunmi
    date accessioned2017-05-08T20:56:15Z
    date available2017-05-08T20:56:15Z
    date copyrightApril 1996
    date issued1996
    identifier other%28asce%290733-9445%281996%29122%3A4%28383%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/32436
    description abstractThis paper presents detailed results on the shear behavior of 2.44 m by 2.44 m light-gauge steel stud walls for three different shear resisting systems: framed walls with 20 gauge flat strap X-bracing on the face—type A; framed walls with 12.5 mm (1/2 in.) single-ply gypsum wallboard on the back and 12.5 mm (1/2 in.) single-ply gypsum sheathing board on the face—type B; and framed walls with 12.5 mm (1/2 in.) single-ply gypsum wallboard on the back, 12.5 mm (1/2 in.) gypsum sheathing board on the face, and 20 gauge flat strap X-bracing on face—type C. The steel framing used in these tests is typical of framing used in residential construction. The behavior of the type A walls was governed by the yield strength of the straps with practically no resistance provided by flexure in the studs. In the type B and type C tests, the measured maximum load was controlled by the breaking of the wallboard along its edges. The failure mechanism was initiated by a rotation of the screws at the edges. This was followed by the partial pull-through of the screws at the edges of the gypsum board and simultaneous breaking of the board at the edges. Each 1.22 m by 2.44 m (4 ft by 8 ft) gypsum panel was observed to behave independently during loading. A comparison of the results from the type B and type C tests showed that the use of 50.8 mm, 20 gauge tension bracing prevented cracking of the boards at the perimeter, reduced the lateral displacement, and increased the maximum load capacity of the wall by as much as 28%.
    publisherAmerican Society of Civil Engineers
    titleShear Resistance of Gypsum-Sheathed Light-Gauge Steel Stud Walls
    typeJournal Paper
    journal volume122
    journal issue4
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(1996)122:4(383)
    treeJournal of Structural Engineering:;1996:;Volume ( 122 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian