    Stress-Strain Model for Confined High-Strength Concrete

    Source: Journal of Structural Engineering:;1995:;Volume ( 121 ):;issue: 003
    Author:
    Daniel Cusson
    ,
    Patrick Paultre
    DOI: 10.1061/(ASCE)0733-9445(1995)121:3(468)
    Publisher: American Society of Civil Engineers
    Abstract: A stress-strain model for confined high-strength concrete has been developed and calibrated against the test results from 50 large-scale high-strength concrete tied columns tested under concentric loading. The effects of the concrete compressive strength, tie yield strength, tie configuration, transverse reinforcement ratio, tie spacing, and longitudinal reinforcement ratio are accounted for in the proposed stress-strain model. The determination of the strength and ductility of confined concrete is based on the computation of the effective confinement pressure, which depends on the stress in the transverse reinforcement at maximum strength of confined concrete, and on the effectively confined concrete area. A method is proposed to compute the stress in the transverse reinforcement at maximum strength of confined concrete.
    • Download: (1.014Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Stress-Strain Model for Confined High-Strength Concrete

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/32191
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorDaniel Cusson
    contributor authorPatrick Paultre
    date accessioned2017-05-08T20:55:52Z
    date available2017-05-08T20:55:52Z
    date copyrightMarch 1995
    date issued1995
    identifier other%28asce%290733-9445%281995%29121%3A3%28468%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/32191
    description abstractA stress-strain model for confined high-strength concrete has been developed and calibrated against the test results from 50 large-scale high-strength concrete tied columns tested under concentric loading. The effects of the concrete compressive strength, tie yield strength, tie configuration, transverse reinforcement ratio, tie spacing, and longitudinal reinforcement ratio are accounted for in the proposed stress-strain model. The determination of the strength and ductility of confined concrete is based on the computation of the effective confinement pressure, which depends on the stress in the transverse reinforcement at maximum strength of confined concrete, and on the effectively confined concrete area. A method is proposed to compute the stress in the transverse reinforcement at maximum strength of confined concrete.
    publisherAmerican Society of Civil Engineers
    titleStress-Strain Model for Confined High-Strength Concrete
    typeJournal Paper
    journal volume121
    journal issue3
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(1995)121:3(468)
    treeJournal of Structural Engineering:;1995:;Volume ( 121 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian