Seismic Responses of Two Adjacent Buildings. I: Data and AnalysesSource: Journal of Structural Engineering:;1993:;Volume ( 119 ):;issue: 008Author:Mehmet Çelebi
DOI: 10.1061/(ASCE)0733-9445(1993)119:8(2461)Publisher: American Society of Civil Engineers
Abstract: In this two‐part paper, responses of two, adjacent, seven‐story buildings in Norwalk, California, to the Whittier‐Narrows, Calif. earthquake of Oct. 1, 1987 are studied. Building A, instrumented according to code recommendations, and building B, extensively instrumented, are offset by 16.3 m from one another. The data set includes motions from the superstructure of both buildings, from a downhole below the foundation of building B, and from three free‐field sites. Part I of the paper includes descriptions of the buildings, site, instrumentation, and analysis of the data of each building. System identification and spectral analysis techniques are employed in part I. Building A has identical first‐mode frequencies of 0.65 Hz for both building axes. The strong‐motion response characteristics of building A are considerably different than those determined from low‐amplitude tests. Building B has fundamental modes at 0.76 Hz and 0.83 Hz in the major and minor axes, respectively. Torsional and diaphragm effects in building B are negligible.
|
Collections
Show full item record
contributor author | Mehmet Çelebi | |
date accessioned | 2017-05-08T20:55:11Z | |
date available | 2017-05-08T20:55:11Z | |
date copyright | August 1993 | |
date issued | 1993 | |
identifier other | %28asce%290733-9445%281993%29119%3A8%282461%29.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/31758 | |
description abstract | In this two‐part paper, responses of two, adjacent, seven‐story buildings in Norwalk, California, to the Whittier‐Narrows, Calif. earthquake of Oct. 1, 1987 are studied. Building A, instrumented according to code recommendations, and building B, extensively instrumented, are offset by 16.3 m from one another. The data set includes motions from the superstructure of both buildings, from a downhole below the foundation of building B, and from three free‐field sites. Part I of the paper includes descriptions of the buildings, site, instrumentation, and analysis of the data of each building. System identification and spectral analysis techniques are employed in part I. Building A has identical first‐mode frequencies of 0.65 Hz for both building axes. The strong‐motion response characteristics of building A are considerably different than those determined from low‐amplitude tests. Building B has fundamental modes at 0.76 Hz and 0.83 Hz in the major and minor axes, respectively. Torsional and diaphragm effects in building B are negligible. | |
publisher | American Society of Civil Engineers | |
title | Seismic Responses of Two Adjacent Buildings. I: Data and Analyses | |
type | Journal Paper | |
journal volume | 119 | |
journal issue | 8 | |
journal title | Journal of Structural Engineering | |
identifier doi | 10.1061/(ASCE)0733-9445(1993)119:8(2461) | |
tree | Journal of Structural Engineering:;1993:;Volume ( 119 ):;issue: 008 | |
contenttype | Fulltext |