contributor author | S. L. Lee | |
contributor author | S. Tumilar | |
contributor author | H. C. Chin | |
date accessioned | 2017-05-08T20:53:34Z | |
date available | 2017-05-08T20:53:34Z | |
date copyright | November 1990 | |
date issued | 1990 | |
identifier other | %28asce%290733-9445%281990%29116%3A11%283077%29.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/30737 | |
description abstract | Architectural and structural considerations in the design of the 27‐story Wisma Dharmala office complex in Jakarta lead to the deployment of twincolumn clusters around the perimeter and interior of the tower block. Due to the large difference in axial loads between the twin columns, excessive differential axial shortening between the columns and high shear stresses in the connecting horizontal structural components are expected. To mitigate this condition, the column load balancing method is proposed, in which the cable profiles in the prestressed girders are designed not only for moment balancing but also to transfer evenly the shear forces in the girders to the twin columns in each cluster. The effect of load balancing is examined in this paper with the use of a simple analytical model. The predicted loads on the columns are also checked against field measurements taken from three pairs of twin columns from the time the columns are cast until the casting of the helipad floor. | |
publisher | American Society of Civil Engineers | |
title | Column Load Balancing in Prestressed Concrete Building | |
type | Journal Paper | |
journal volume | 116 | |
journal issue | 11 | |
journal title | Journal of Structural Engineering | |
identifier doi | 10.1061/(ASCE)0733-9445(1990)116:11(3077) | |
tree | Journal of Structural Engineering:;1990:;Volume ( 116 ):;issue: 011 | |
contenttype | Fulltext | |