| contributor author | Alok Goyal | |
| contributor author | Anil K. Chopra | |
| date accessioned | 2017-05-08T20:53:22Z | |
| date available | 2017-05-08T20:53:22Z | |
| date copyright | June 1989 | |
| date issued | 1989 | |
| identifier other | %28asce%290733-9445%281989%29115%3A6%281371%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/30599 | |
| description abstract | The linear responses of idealized intake‐outlet towers to harmonic ground motion are presented for a range of parameters characterizing the tower geometry, surrounding and inside water, and foundation‐soil system. Based on these frequency response functions, the effects of tower‐water interaction and tower‐foundation‐soil interaction on the response of towers are identified and shown to be significant in many cases. | |
| publisher | American Society of Civil Engineers | |
| title | Hydrodynamic and Foundation Interaction Effects in Dynamics of Intake Towers: Frequency Response Functions | |
| type | Journal Paper | |
| journal volume | 115 | |
| journal issue | 6 | |
| journal title | Journal of Structural Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9445(1989)115:6(1371) | |
| tree | Journal of Structural Engineering:;1989:;Volume ( 115 ):;issue: 006 | |
| contenttype | Fulltext | |