Experimental Analysis of Local Pressure Losses for Microirrigation LateralsSource: Journal of Irrigation and Drainage Engineering:;2004:;Volume ( 130 ):;issue: 004DOI: 10.1061/(ASCE)0733-9437(2004)130:4(318)Publisher: American Society of Civil Engineers
Abstract: The accurate design of drip irrigation laterals needs to consider the variation of hydraulic head due to pipe elevation changes, head losses along the lines, and also, at a given operating pressure, emitter discharge variations related to manufacturing variability, clogging, and water temperature. Hydraulic head variations are consequent to both the friction losses and local losses due to the in-line or on-line emitters along the pipe, which determine the contraction and subsequent enlargement of the flow streamlines. Moreover, in-line emitters usually have a smaller diameter than the pipe, and therefore an additional friction loss must be considered. Evaluation of energy losses and consequently the design of drip irrigation lines is usually carried out by assuming the hypothesis that local losses can be neglected, even if previous experimental researches showed that local losses can become a significant percentage of total head losses as a consequence of the high number of emitters installed along the lines. This paper reports the results of an experimental investigation to evaluate local losses in integrated laterals in which coextruded emitters are installed inside the pipe. Local losses were measured for 10 different types of commercially available integrated laterals and for different Reynolds numbers. A practical power relationship was deduced between the α coefficient, expressing the amount of local losses as a fraction of the kinetic head, and a simple geometric parameter characterizing the geometry of the emitter and the pipe. Local losses obtained for integrated laterals were then compared with those due to the on-line emitters, previously determined as a function of the pipe-emitter geometry. The proposed criterion for calculating the local losses was finally verified by using a step-by-step procedure.
|
Collections
Show full item record
contributor author | Giuseppe Provenzano | |
contributor author | Domenico Pumo | |
date accessioned | 2017-05-08T20:49:27Z | |
date available | 2017-05-08T20:49:27Z | |
date copyright | August 2004 | |
date issued | 2004 | |
identifier other | %28asce%290733-9437%282004%29130%3A4%28318%29.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/28270 | |
description abstract | The accurate design of drip irrigation laterals needs to consider the variation of hydraulic head due to pipe elevation changes, head losses along the lines, and also, at a given operating pressure, emitter discharge variations related to manufacturing variability, clogging, and water temperature. Hydraulic head variations are consequent to both the friction losses and local losses due to the in-line or on-line emitters along the pipe, which determine the contraction and subsequent enlargement of the flow streamlines. Moreover, in-line emitters usually have a smaller diameter than the pipe, and therefore an additional friction loss must be considered. Evaluation of energy losses and consequently the design of drip irrigation lines is usually carried out by assuming the hypothesis that local losses can be neglected, even if previous experimental researches showed that local losses can become a significant percentage of total head losses as a consequence of the high number of emitters installed along the lines. This paper reports the results of an experimental investigation to evaluate local losses in integrated laterals in which coextruded emitters are installed inside the pipe. Local losses were measured for 10 different types of commercially available integrated laterals and for different Reynolds numbers. A practical power relationship was deduced between the α coefficient, expressing the amount of local losses as a fraction of the kinetic head, and a simple geometric parameter characterizing the geometry of the emitter and the pipe. Local losses obtained for integrated laterals were then compared with those due to the on-line emitters, previously determined as a function of the pipe-emitter geometry. The proposed criterion for calculating the local losses was finally verified by using a step-by-step procedure. | |
publisher | American Society of Civil Engineers | |
title | Experimental Analysis of Local Pressure Losses for Microirrigation Laterals | |
type | Journal Paper | |
journal volume | 130 | |
journal issue | 4 | |
journal title | Journal of Irrigation and Drainage Engineering | |
identifier doi | 10.1061/(ASCE)0733-9437(2004)130:4(318) | |
tree | Journal of Irrigation and Drainage Engineering:;2004:;Volume ( 130 ):;issue: 004 | |
contenttype | Fulltext |