Friction Correction Factors for Center-PivotsSource: Journal of Irrigation and Drainage Engineering:;1999:;Volume ( 125 ):;issue: 005Author:Arif A. Anwar
DOI: 10.1061/(ASCE)0733-9437(1999)125:5(280)Publisher: American Society of Civil Engineers
Abstract: Analytical equations for friction correction factors for center-pivot laterals without end guns are developed. This work illustrates a discrepancy when earlier equations are applied to center-pivots with small numbers of outlets. Earlier equations were also limited to center-pivots with constant outlet spacing. Equations presented in the current work are developed for center-pivots with constant outlet spacing and also for center-pivots with constant outlet discharge. When the equations developed in the current work are applied to center-pivots with a large number of outlets, the results are in good agreement with previous work for center-pivot laterals with an infinite number of outlets. When applied to a smaller number of outlets the equations presented here provide a more precise estimate of the friction correction factor. Using the current equations, the friction correction factor for center-pivots with constant outlet spacing was found to be very similar to the friction correction factor for center-pivots with constant outlet discharge. Useful simple equations are also presented for calculating the discharge of each outlet or for calculating the spacing between outlets.
|
Collections
Show full item record
| contributor author | Arif A. Anwar | |
| date accessioned | 2017-05-08T20:48:59Z | |
| date available | 2017-05-08T20:48:59Z | |
| date copyright | October 1999 | |
| date issued | 1999 | |
| identifier other | %28asce%290733-9437%281999%29125%3A5%28280%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/27933 | |
| description abstract | Analytical equations for friction correction factors for center-pivot laterals without end guns are developed. This work illustrates a discrepancy when earlier equations are applied to center-pivots with small numbers of outlets. Earlier equations were also limited to center-pivots with constant outlet spacing. Equations presented in the current work are developed for center-pivots with constant outlet spacing and also for center-pivots with constant outlet discharge. When the equations developed in the current work are applied to center-pivots with a large number of outlets, the results are in good agreement with previous work for center-pivot laterals with an infinite number of outlets. When applied to a smaller number of outlets the equations presented here provide a more precise estimate of the friction correction factor. Using the current equations, the friction correction factor for center-pivots with constant outlet spacing was found to be very similar to the friction correction factor for center-pivots with constant outlet discharge. Useful simple equations are also presented for calculating the discharge of each outlet or for calculating the spacing between outlets. | |
| publisher | American Society of Civil Engineers | |
| title | Friction Correction Factors for Center-Pivots | |
| type | Journal Paper | |
| journal volume | 125 | |
| journal issue | 5 | |
| journal title | Journal of Irrigation and Drainage Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9437(1999)125:5(280) | |
| tree | Journal of Irrigation and Drainage Engineering:;1999:;Volume ( 125 ):;issue: 005 | |
| contenttype | Fulltext |