    Kettleman Hills Waste Landfill Slope Failure. II: Stability Analyses

    Source: Journal of Geotechnical Engineering:;1990:;Volume ( 116 ):;issue: 004
    Author:
    Raymond B. Seed
    ,
    James K. Mitchell
    ,
    H. Bolton Seed
    DOI: 10.1061/(ASCE)0733-9410(1990)116:4(669)
    Publisher: American Society of Civil Engineers
    Abstract: Analyses were made to determine the cause of a stability failure of a 90 ft high, 15 acre hazardous waste landfill in which lateral displacements of up to 35 ft and vertical settlements of up to 14 ft were measured. The failure developed by sliding along interfaces within the composite geosynthetic‐compacted‐clay liner system beneath the waste fill. The shear resistances of the different interfaces in the liner system were determined by direct shear and pullout tests as described in a companion paper (Mitchell et al. 1990). Conventional two‐dimensional (2D) stability analyses of representative cross sections and three‐dimensional (3D) analyses of the overall waste fill and liner configuration are described. Each type of analysis was applied to two cases: (1) The “Probable Minimum Clay/Liner Wetting Case,” in which shear along a wetted HDPE liner/compacted clay interface was assumed to occur only over a small area of the base; and (2) the “Full‐Base‐Wetting Case,” in which the HDPE liner/compacted clay liner interface was assumed to have become “wetted” over the full central base of the fill basin. The 2D stability analyses gave factors of safety of 1.2‐1.25 and 1.1‐1.15 for the minimum wetting case and the full base wetting case, respectively, while the 3D analyses yielded values of 1.08 and 1.01 for these two cases. Uncertainties in the strength parameters and analysis methods lead to a best estimate of the computed factor of safety at the time of failure of 0.85‐1.25.This provides good agreement with the observed field performance, and suggests that the techniques used to evaluate liner‐interface shear strengths and to perform overall stability analyses may be appropriate for future evaluation of other, similar lined waste‐repository fills.
    • Download: (1.729Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Kettleman Hills Waste Landfill Slope Failure. II: Stability Analyses

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/20623
    Collections
    • Journal of Geotechnical Engineering

    Show full item record

    contributor authorRaymond B. Seed
    contributor authorJames K. Mitchell
    contributor authorH. Bolton Seed
    date accessioned2017-05-08T20:35:41Z
    date available2017-05-08T20:35:41Z
    date copyrightApril 1990
    date issued1990
    identifier other%28asce%290733-9410%281990%29116%3A4%28669%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/20623
    description abstractAnalyses were made to determine the cause of a stability failure of a 90 ft high, 15 acre hazardous waste landfill in which lateral displacements of up to 35 ft and vertical settlements of up to 14 ft were measured. The failure developed by sliding along interfaces within the composite geosynthetic‐compacted‐clay liner system beneath the waste fill. The shear resistances of the different interfaces in the liner system were determined by direct shear and pullout tests as described in a companion paper (Mitchell et al. 1990). Conventional two‐dimensional (2D) stability analyses of representative cross sections and three‐dimensional (3D) analyses of the overall waste fill and liner configuration are described. Each type of analysis was applied to two cases: (1) The “Probable Minimum Clay/Liner Wetting Case,” in which shear along a wetted HDPE liner/compacted clay interface was assumed to occur only over a small area of the base; and (2) the “Full‐Base‐Wetting Case,” in which the HDPE liner/compacted clay liner interface was assumed to have become “wetted” over the full central base of the fill basin. The 2D stability analyses gave factors of safety of 1.2‐1.25 and 1.1‐1.15 for the minimum wetting case and the full base wetting case, respectively, while the 3D analyses yielded values of 1.08 and 1.01 for these two cases. Uncertainties in the strength parameters and analysis methods lead to a best estimate of the computed factor of safety at the time of failure of 0.85‐1.25.This provides good agreement with the observed field performance, and suggests that the techniques used to evaluate liner‐interface shear strengths and to perform overall stability analyses may be appropriate for future evaluation of other, similar lined waste‐repository fills.
    publisherAmerican Society of Civil Engineers
    titleKettleman Hills Waste Landfill Slope Failure. II: Stability Analyses
    typeJournal Paper
    journal volume116
    journal issue4
    journal titleJournal of Geotechnical Engineering
    identifier doi10.1061/(ASCE)0733-9410(1990)116:4(669)
    treeJournal of Geotechnical Engineering:;1990:;Volume ( 116 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian