contributor author | Donald A. F. Colwell | |
contributor author | Samuel T. Ariaratnam | |
date accessioned | 2017-05-08T20:35:40Z | |
date available | 2017-05-08T20:35:40Z | |
date copyright | February 2003 | |
date issued | 2003 | |
identifier other | %28asce%290733-9364%282003%29129%3A1%2847%29.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/20621 | |
description abstract | This paper presents the results of field installations of high-density polyethylene (HDPE) using the horizontal directional drilling process. One each of 114 mm (4 in.) diameter standard dimension ratio (SDR) 17 HDPE pipe, 219 mm (8 in.) diameter SDR 17 HDPE pipe, and 324 mm (12 in.) diameter SDR 17 HDPE pipe were installed in a cohesionless soil medium. Various testing parameters were captured during the pullback phase of these three installations. These testing parameters consisted of utilizing pressure transducers to capture the pullback and rotational pressures on the drilling rig, installing linear potentiometers inside the HDPE pipe to measure the axial strain on the pipe, and applying an external load cell to quantify the loading on the pipe during the pullback phase. Comparisons of the pullback and rotational pressure on the drilling rig, loading on the HDPE pipe, and average and maximum strain experienced by the HDPE pipe are presented with respect to the installed pipe diameter. | |
publisher | American Society of Civil Engineers | |
title | Evaluation of High-Density Polyethylene Pipe Installed Using Horizontal Directional Drilling | |
type | Journal Paper | |
journal volume | 129 | |
journal issue | 1 | |
journal title | Journal of Construction Engineering and Management | |
identifier doi | 10.1061/(ASCE)0733-9364(2003)129:1(47) | |
tree | Journal of Construction Engineering and Management:;2003:;Volume ( 129 ):;issue: 001 | |
contenttype | Fulltext | |