Show simple item record

contributor authorVenkateshwarlu, K.
contributor authorNayak, A. K.
contributor authorSingh, Bhupinder
contributor authorKatiyar, V. K.
contributor authorGupta, N.
date accessioned2017-05-09T01:30:05Z
date available2017-05-09T01:30:05Z
date issued2016
identifier issn0022-1481
identifier otherht_138_03_032501.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/161519
description abstractAirflow, heat, and contaminant transfer in a mechanically ventilated twodimensional rectangular enclosure by discrete heat and contaminant sources as well as external forced convection at various inlet and outlet locations is numerically simulated. Two different enclosure configurations are considered. In configuration A, the cold air is injected at the top of the left vertical wall and exited at the bottom of the right vertical wall. In configuration B, the cold air is injected at the lower edge of the left vertical wall and exited at the top of the right vertical wall. The objective of the study is to find the relative locations of inlet and outlet in order to obtain more effective cooling in the core of the enclosure by maximizing the heat and contaminant removal rate and reducing the overall temperature. The developed mathematical model is governed by the twodimensional continuity, momentum, energy, and concentration equations. The governing equations in Cartesian coordinates are solved by finite volume based semiimplicit method for pressure linkedequations (SIMPLE) algorithm based on a staggered grid system. Results are presented for different values of the Reynolds number, Grashof number, Sherwood number, and Buoyancy ratio in the laminar regime. A convective transport visualization technique is used to study the behavior of physical phenomena due to stream function, thermal, and solutal functions. The results indicate that cooling inside the core of the enclosure is most effective when the inlet is kept at the bottom of the left vertical wall.
publisherThe American Society of Mechanical Engineers (ASME)
titleThermosolutal Mixed Convection in an Air Filled Ventilated Enclosure With Slot Wise Embedded Heat and Contaminant Sources
typeJournal Paper
journal volume138
journal issue3
journal titleJournal of Heat Transfer
identifier doi10.1115/1.4031788
journal fristpage32501
journal lastpage32501
identifier eissn1528-8943
treeJournal of Heat Transfer:;2016:;volume( 138 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record