contributor author | Al Ba'ba'a, Hasan B. | |
contributor author | Elgammal, Tarek | |
contributor author | Amano, Ryoichi S. | |
date accessioned | 2017-05-09T01:29:53Z | |
date available | 2017-05-09T01:29:53Z | |
date issued | 2016 | |
identifier issn | 0098-2202 | |
identifier other | fe_138_11_114501.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/161452 | |
description abstract | Prediction correlations of air bubble diameter and frequency in stagnant clean water were established. Eleven different orifice diameters were tested under flow rate of 0.05–0.15 SLPM. The resulted bubble size and frequency were traced using highspeed camera. It was found that the mean Sauter diameter and bubble frequency are in the range of 3.7–6.9 mm and 6.4–47.2 bubbles per second, respectively. Nonlinear regression was performed to design the new correlations of estimating diameter and frequency with a correlation factor of 0.93 and 0.94, respectively. Flow rate and orifice size had the highest impact on the studied parameters. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Correlations of Bubble Diameter and Frequency for Air–Water System Based on Orifice Diameter and Flow Rate | |
type | Journal Paper | |
journal volume | 138 | |
journal issue | 11 | |
journal title | Journal of Fluids Engineering | |
identifier doi | 10.1115/1.4033749 | |
journal fristpage | 114501 | |
journal lastpage | 114501 | |
identifier eissn | 1528-901X | |
tree | Journal of Fluids Engineering:;2016:;volume( 138 ):;issue: 011 | |
contenttype | Fulltext | |