description abstractSome oil pump station design layouts may contain multiple deadlegs. During the transportation of heavy crude through the pump station, these deadlegs will be filled with this crude. When a light crude batch is introduced next into the pipeline, following the heavy crude ahead, two phenomena will occur. First, contamination between batches at the interface of the two crudes will occur due to axial turbulent diffusion along the length of the pipeline itself. Second, as the light crude flows through the pump station and passes by each deadleg containing still heavy crude from the preceding batch, the heavy crude trapped in these deadlegs will start to drain out into the passing light crude in the main run. This causes further contamination and spreading of the mixing zone between the two batches. These two different sources of contamination are addressed in this paper with the objective of accurately quantifying the extent of the contamination, with particular emphasis on the second phenomenon which could cause appreciable contamination particularly for large size and number of these deadlegs. A computational fluid dynamics (CFD) model has been developed to quantify the drainage rate of the contaminating crude into the main stream and its impact on widening the mixed zone (contamination spread) between the two batches. Two drainage mechanisms of the heavy crude in the deadlegs into the main stream of the light crude have been identified and quantified. The initial phase is a gravitycurrentinduced outflow of the initially stagnant fluid in the deadleg, followed by a subsequent draining mechanism primarily induced by turbulent mixing and diffusion at the mouth of the deadleg penetrating slightly into the deadleg. It was found that the second mechanism takes a much longer time to drain the first, and that the break point in time where drainage switches from a predominantly gravity current to a turbulent diffusion appears to be at a specific time normalized with respect to the length of the deadleg and the gravity current speed. The results show a consistent trend with actual interface contamination data obtained from the Keystone 2982 km pipeline from Hardisty (Canada) to the Patoka Terminal (U.S.A.).
publisherThe American Society of Mechanical Engineers (ASME)
titleInterfacial Contamination Between Batches of Crude Oil Due to Dead Legs in Pump Station Piping
typeJournal Paper
journal volume138
journal issue5
journal titleJournal of Energy Resources Technology
identifier doi10.1115/1.4033401
journal fristpage52908
journal lastpage52908
identifier eissn1528-8994
treeJournal of Energy Resources Technology:;2016:;volume( 138 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record