Show simple item record

contributor authorZhao, Kristin D.
contributor authorBen
contributor authorMagnuson, Dixon J.
contributor authorCamp, Jon J.
contributor authorBerglund, Lawrence J.
contributor authorAn, Kai
contributor authorBronfort, Gert
contributor authorGay, Ralph E.
date accessioned2017-05-09T01:26:10Z
date available2017-05-09T01:26:10Z
date issued2016
identifier issn0148-0731
identifier otherbio_138_05_054502.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160405
description abstractSpine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, twodimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of Carm rotation to simulate offaxis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each offaxis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the offaxis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffect of Off Axis Fluoroscopy Imaging on Two Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
typeJournal Paper
journal volume138
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4032995
journal fristpage54502
journal lastpage54502
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record