Show simple item record

contributor authorMoissenet, Florent
contributor authorChأ¨ze, Laurence
contributor authorDumas, Raphaأ«l
date accessioned2017-05-09T01:25:57Z
date available2017-05-09T01:25:57Z
date issued2016
identifier issn0148-0731
identifier otherbio_138_02_021019.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160346
description abstractWhile recent literature has clearly demonstrated that an extensive personalization of the musculoskeletal models was necessary to reach high accuracy, several components of the generic models may be further investigated before defining subjectspecific parameters. Among others, the choice in muscular geometry and thus the level of muscular redundancy in the model may have a noticeable influence on the predicted musculotendon and joint contact forces. In this context, the aim of this study was to investigate if the level of muscular redundancy can contribute or not to reduce inaccuracies in tibiofemoral contact forces predictions. For that, the dataset disseminated through the Sixth Grand Challenge Competition to Predict In Vivo Knee Loads was applied to a versatile 3D lower limb musculoskeletal model in which two muscular geometries (i.e., two different levels of muscular redundancy) were implemented. This dataset provides tibiofemoral implant measurements for both medial and lateral compartments and thus allows evaluation of the validity of the model predictions. The results suggest that an increase of the level of muscular redundancy corresponds to a better accuracy of total tibiofemoral contact force whatever the gait pattern investigated. However, the medial and lateral contact forces ratio and accuracy were not necessarily improved when increasing the level of muscular redundancy and may thus be attributed to other parameters such as the location of contact points. To conclude, the muscular geometry, among other components of the generic model, has a noticeable impact on joint contact forces predictions and may thus be correctly chosen even before trying to personalize the model.
publisherThe American Society of Mechanical Engineers (ASME)
titleInfluence of the Level of Muscular Redundancy on the Validity of a Musculoskeletal Model
typeJournal Paper
journal volume138
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4032127
journal fristpage21019
journal lastpage21019
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record