description abstract | Otologic surgery often involves a mastoidectomy, which is the removal of a portion of the mastoid region of the temporal bone, to safely access the middle and inner ear. The surgery is challenging because many critical structures are embedded within the bone, making them difficult to see and requiring a high level of accuracy with the surgical dissection instrument, a highspeed drill. We propose to automate the mastoidectomy portion of the surgery using a compact, boneattached robot. The system described in this paper is a milling robot with four degreesoffreedom (DOF) that is fixed to the patient during surgery using a rigid positioning frame screwed into the surface of the bone. The target volume to be removed is manually identified by the surgeon preoperatively in a computed tomography (CT) scan and converted to a milling path for the robot. The surgeon attaches the robot to the patient in the operating room and monitors the procedure. Several design considerations are discussed in the paper as well as the proposed surgical workflow. The mean targeting error of the system in free space was measured to be 0.5 mm or less at vital structures. Four mastoidectomies were then performed in cadaveric temporal bones, and the error at the edges of the target volume was measured by registering a postoperative computed tomography (CT) to the preoperative CT. The mean error along the border of the milled cavity was 0.38 mm, and all critical anatomical structures were preserved. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | A Compact, Bone Attached Robot for Mastoidectomy | |
type | Journal Paper | |
journal volume | 9 | |
journal issue | 3 | |
journal title | Journal of Medical Devices | |
identifier doi | 10.1115/1.4030083 | |
journal fristpage | 31003 | |
journal lastpage | 31003 | |
identifier eissn | 1932-619X | |
tree | Journal of Medical Devices:;2015:;volume( 009 ):;issue: 003 | |
contenttype | Fulltext | |