Show simple item record

contributor authorZhang, Will
contributor authorFeng, Yuan
contributor authorLee, Chung
contributor authorBilliar, Kristen L.
contributor authorSacks, Michael S.
date accessioned2017-05-09T01:15:15Z
date available2017-05-09T01:15:15Z
date issued2015
identifier issn0148-0731
identifier otherbio_137_06_064501.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157137
description abstractSimulation of the mechanical behavior of soft tissues is critical for many physiological and medical device applications. Accurate mechanical test data is crucial for both obtaining the form and robust parameter determination of the constitutive model. For incompressible soft tissues that are either membranes or thin sections, planar biaxial mechanical testing configurations can provide much information about the anisotropic stress–strain behavior. However, the analysis of soft biological tissue planar biaxial mechanical test data can be complicated by inplane shear, tissue heterogeneities, and inelastic changes in specimen geometry that commonly occur during testing. These inelastic effects, without appropriate corrections, alter the stresstraction mapping and violates equilibrium so that the stress tensor is incorrectly determined. To overcome these problems, we presented an analytical method to determine the Cauchy stress tensor from the experimentally derived tractions for tethered testing configurations. We accounted for the measured testing geometry and compensate for runtime inelastic effects by enforcing equilibrium using small rigid body rotations. To evaluate the effectiveness of our method, we simulated complete planar biaxial test configurations that incorporated actual device mechanisms, specimen geometry, and heterogeneous tissue fibrous structure using a finite element (FE) model. We determined that our method corrected the errors in the equilibrium of momentum and correctly estimated the Cauchy stress tensor. We also noted that since stress is applied primarily over a subregion bounded by the tethers, an adjustment to the effective specimen dimensions is required to correct the magnitude of the stresses. Simulations of various tether placements demonstrated that typical tether placements used in the current experimental setups will produce accurate stress tensor estimates. Overall, our method provides an improved and relatively straightforward method of calculating the resulting stresses for planar biaxial experiments for tethered configurations, which is especially useful for specimens that undergo large shear and exhibit substantial inelastic effects.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Generalized Method for the Analysis of Planar Biaxial Mechanical Data Using Tethered Testing Configurations
typeJournal Paper
journal volume137
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4029266
journal fristpage64501
journal lastpage64501
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record