Show simple item record

contributor authorFlegel, C.
contributor authorSingal, K.
contributor authorRajamani, R.
contributor authorOdland, R.
date accessioned2017-05-09T01:11:02Z
date available2017-05-09T01:11:02Z
date issued2014
identifier issn1932-6181
identifier othermed_008_01_011008.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/155805
description abstractCompartment syndrome is a major concern in cases of extremity trauma, which occur in over 70% of military combat casualty. Without treatment, compartment syndrome can lead to paralysis, loss of limb, or death. This paper focuses on the development of a handheld sensor that can be used for the noninvasive diagnosis of compartment syndrome. Analytical development of the sensing principle is first presented in which a relation is obtained between the pressure in a fluid compartment and the stiffness experienced by a handheld probe pushing on the compartment. Then a handheld sensor that can measure stiffness of an object without requiring the use of any inertial reference is presented. The handheld sensor consists of an array of three miniature forcesensing spring loaded pistons placed together on a probe. The center spring is chosen to be significantly stiffer than the side springs. The ratio of forces between the stiff and soft springs is proportional to the stiffness of the soft object against which the probe is pushed. Small millimetersized magnets on the pistons and magnetic field measurement chips are used to measure the forces in the individual pistons. Experimental results are presented using both an in vitro pneumatic test rig and a compliant agarose gel chamber that replicates a fluid pressure compartment. The sensor is shown to measure pressure accurately with a resolution of 0.1 psi over the range 0.75–2.5 psi. The developed sensor has the potential to be useful for convenient handheld diagnosis of compartment syndrome in traumatic extremity injuries.
publisherThe American Society of Mechanical Engineers (ASME)
titleDevelopment and Experimental Validation of A Handheld Noninvasive Sensor for the Measurement of Compartment Pressures
typeJournal Paper
journal volume8
journal issue1
journal titleJournal of Medical Devices
identifier doi10.1115/1.4026295
journal fristpage11008
journal lastpage11008
identifier eissn1932-619X
treeJournal of Medical Devices:;2014:;volume( 008 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record