Accelerated Method for Surface View Factor Evaluation Based on Error Estimation
| contributor author | Koptelov, Roman | |
| contributor author | Malikov, German | |
| contributor author | Lisienko, Vladimir | |
| contributor author | Viskanta, Raymond | |
| date accessioned | 2017-05-09T01:09:31Z | |
| date available | 2017-05-09T01:09:31Z | |
| date issued | 2014 | |
| identifier issn | 0022-1481 | |
| identifier other | ht_136_07_074502.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/155310 | |
| description abstract | An algorithm for choosing the number of quadrature nodes before calculation of a view factor is proposed. Simple criterion is introduced that allows one to estimate the error in the computed view factor. The algorithm allows one to save much computation time by always using the minimum number of nodes for each pair of surface zones and insures a desired accuracy. The algorithm is applied for model of a continuous furnace and is compared with a standard method which uses predefined number of nodes at each surface. The proposed algorithm is many times faster and also more accurate than the standard one. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Accelerated Method for Surface View Factor Evaluation Based on Error Estimation | |
| type | Journal Paper | |
| journal volume | 136 | |
| journal issue | 7 | |
| journal title | Journal of Heat Transfer | |
| identifier doi | 10.1115/1.4027251 | |
| journal fristpage | 74502 | |
| journal lastpage | 74502 | |
| identifier eissn | 1528-8943 | |
| tree | Journal of Heat Transfer:;2014:;volume( 136 ):;issue: 007 | |
| contenttype | Fulltext |