Show simple item record

contributor authorKang, Hie Chan
contributor authorCho, Hyejung
contributor authorKim, Jin Ho
contributor authorJacobi, Anthony M.
date accessioned2017-05-09T01:09:04Z
date available2017-05-09T01:09:04Z
date issued2014
identifier issn2381-6872
identifier otherfc_011_04_041004.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/155137
description abstractThe present work is performed to evaluate the heat transfer performance of a heat exchanger used in a direct methanol fuel cell. Because of material constraints and performance requirements, a louver fin heat exchanger is modified for use with conventional microchannel tubes and also with multiple smalldiameter tubes (called multitubes). Prototype heat exchangers are tested, and the airside heat transfer, pressure drop, and fan power are measured in a wind tunnel and simulated using a commercial code. The airside pressure drop and heat transfer coefficient of the multitubes show similar trends to those of the flattube heat exchanger if the contact resistance is negligible. The tube spacing of the prototype multitube heat exchangers has a small effect on the pressure drop and heat transfer, but it has a profound effect on the airside heat transfer performance because of the contact resistance between the tubes and louver fins. The airside pressure drop agrees well with an empirical correlation for flat tubes.
publisherThe American Society of Mechanical Engineers (ASME)
titleAir Side Heat Transfer Performance of Louver Fin and Multitube Heat Exchanger for Direct Methanol Fuel Cell Cooling Application
typeJournal Paper
journal volume11
journal issue4
journal titleJournal of Fuel Cell Science and Technology
identifier doi10.1115/1.4026955
journal fristpage41004
journal lastpage41004
identifier eissn2381-6910
treeJournal of Fuel Cell Science and Technology:;2014:;volume( 011 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record