Show simple item record

contributor authorKheyfets, Vitaly O.
contributor authorThornton, Rita C.
contributor authorKowal, Mikala
contributor authorFinol, Ender A.
date accessioned2017-05-09T01:05:31Z
date available2017-05-09T01:05:31Z
date issued2014
identifier issn0148-0731
identifier otherbio_136_07_074501.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154038
description abstractSkin wounds and burns compromise the body's natural barrier to bacteria and other pathogens. While many forms of wound dressings are available, polymeric films are advantageous for various reasons, ranging from the ease of application to durability. One common drawback of using polymeric films for a wound bandage is that the films tend to adhere to common inanimate objects. Patients spend hours in contact with soft and hard materials pressed against their skin, which, if the skin was dressed with a polymeric film, would inflict further wound damage upon body movement. In this work, we present a novel technique that allowed for measuring polymeric tackiness, after a long incubation period, with materials regularly encountered in a hospital or home setting, and soft fabrics. The polymers were exposed to an environment intended to simulate daily conditions and the technique is designed to perform multiple experiments simultaneously with ease. Four commercially available polymers (newskin, nosting skinprep, skin shield, and Silesse) were tested as proofofconcept to gather preliminary data for an overall assessment of wound treatment efficacy, resulting in the estimation of pulloff stress of the polymers from a specimen of porcine skin. Silesse did not reveal a measurable tackiness, nosting skinprep had the highest mean tackiness (13.8 kPa), while the mean tackiness between newskin and skin shield was approximately equal (9.8 kPa vs. 10.1 kPa, respectively), p = 0.05. Future work on polymeric fluids for wound dressing applications should include tensile stress and dynamic viscosity estimations.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Protocol for Measuring Pull off Stress of Wound Treatment Polymers
typeJournal Paper
journal volume136
journal issue7
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4027412
journal fristpage74501
journal lastpage74501
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 007