Show simple item record

contributor authorSander, Edward A.
contributor authorLynch, Kaari A.
contributor authorBoyce, Steven T.
date accessioned2017-05-09T01:05:25Z
date available2017-05-09T01:05:25Z
date issued2014
identifier issn0148-0731
identifier otherbio_136_05_051008.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154005
description abstractEngineered skin substitutes (ESSs) have been reported to close fullthickness burn wounds but are subject to loss from mechanical shear due to their deficiencies in tensile strength and elasticity. Hypothetically, if the mechanical properties of ESS matched those of native skin, losses due to shear or fracture could be reduced. To consider modifications of the composition of ESS to improve homology with native skin, biomechanical analyses of the current composition of ESS were performed. ESSs consist of a degradable biopolymer scaffold of type I collagen and chondroitinsulfate (CGS) that is populated sequentially with cultured human dermal fibroblasts (hF) and epidermal keratinocytes (hK). In the current study, the hydrated biopolymer scaffold (CGS), the scaffold populated with hF dermal skin substitute (DSS), or the complete ESS were evaluated mechanically for linear stiffness (N/mm), ultimate tensile load at failure (N), maximum extension at failure (mm), and energy absorbed up to the point of failure (Nmm). These biomechanical end points were also used to evaluate ESS at six weeks after grafting to fullthickness skin wounds in athymic mice and compared to murine autograft or excised murine skin. The data showed statistically significant differences (p <0.05) between ESS in vitro and after grafting for all four structural properties. Grafted ESS differed statistically from murine autograft with respect to maximum extension at failure, and from intact murine skin with respect to linear stiffness and maximum extension. These results demonstrate rapid changes in mechanical properties of ESS after grafting that are comparable to murine autograft. These values provide instruction for improvement of the biomechanical properties of ESS in vitro that may reduce clinical morbidity from graft loss.
publisherThe American Society of Mechanical Engineers (ASME)
titleDevelopment of the Mechanical Properties of Engineered Skin Substitutes After Grafting to Full Thickness Wounds
typeJournal Paper
journal volume136
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4026290
journal fristpage51008
journal lastpage51008
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record