Show simple item record

contributor authorAiyangar, Ameet K.
contributor authorZheng, Liying
contributor authorTashman, Scott
contributor authorAnderst, William J.
contributor authorZhang, Xudong
date accessioned2017-05-09T01:05:06Z
date available2017-05-09T01:05:06Z
date issued2014
identifier issn0148-0731
identifier otherbio_136_01_011004.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/153918
description abstractAvailability of accurate threedimensional (3D) kinematics of lumbar vertebrae is necessary to understand normal and pathological biomechanics of the lumbar spine. Due to the technical challenges of imaging the lumbar spine motion in vivo, it has been difficult to obtain comprehensive, 3D lumbar kinematics during dynamic functional tasks. The present study demonstrates a recently developed technique to acquire true 3D lumbar vertebral kinematics, in vivo, during a functional loadlifting task. The technique uses a highspeed dynamic stereoradiography (DSX) system coupled with a volumetric modelbased bone tracking procedure. Eight asymptomatic male participants performed weightlifting tasks, while dynamic Xray images of their lumbar spines were acquired at 30 fps. A customdesigned radiation attenuator reduced the radiation whiteout effect and enhanced the image quality. High resolution CT scans of participants' lumbar spines were obtained to create 3D bone models, which were used to track the Xray images via a volumetric bone tracking procedure. Continuous 3D intervertebral kinematics from the second lumbar vertebra (L2) to the sacrum (S1) were derived. Results revealed motions occurring simultaneously in all the segments. Differences in contributions to overall lumbar motion from individual segments, particularly L2–L3, L3–L4, and L4–L5, were not statistically significant. However, a reduced contribution from the L5–S1 segment was observed. Segmental extension was nominally linear in the middle range (20%–80%) of motion during the lifting task, but exhibited nonlinear behavior at the beginning and end of the motion. L5–S1 extension exhibited the greatest nonlinearity and variability across participants. Substantial AP translations occurred in all segments (5.0 آ±â€‰0.3 mm) and exhibited more scatter and deviation from a nominally linear path compared to segmental extension. Maximum outofplane rotations (<1.91 deg) and translations (<0.94 mm) were small compared to the dominant motion in the sagittal plane. The demonstrated success in capturing continuous 3D in vivo lumbar intervertebral kinematics during functional tasks affords the possibility to create a baseline data set for evaluating the lumbar spinal function. The technique can be used to address the gaps in knowledge of lumbar kinematics, to improve the accuracy of the kinematic input into biomechanical models, and to support development of new disk replacement designs more closely replicating the natural lumbar biomechanics.
publisherThe American Society of Mechanical Engineers (ASME)
titleCapturing Three Dimensional In Vivo Lumbar Intervertebral Joint Kinematics Using Dynamic Stereo X Ray Imaging
typeJournal Paper
journal volume136
journal issue1
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4025793
journal fristpage11004
journal lastpage11004
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 001