Show simple item record

contributor authorRoberts, William B.
contributor authorThorp, Scott A.
contributor authorPrahst, Patricia S.
contributor authorStrazisar, Anthony J.
date accessioned2017-05-09T01:03:14Z
date available2017-05-09T01:03:14Z
date issued2013
identifier issn0889-504X
identifier otherturb_135_1_011001.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/153360
description abstractBacktoback testing was done using NASA fan rotor 67 in the Glenn Research Center W8 Axial Compressor Test Facility. The rotor was baseline tested with a normal industrial rootmeansquare (RMS) surface finish of 0.5 خ¼m to 0.6 خ¼m (20 microinches to 24 microinches) at 60, 80, and 100% of design speed. At design speed the tip relative Mach number was 1.38. The blades were then removed from the facility and ultrapolished to a surface finish of 0.125 خ¼m (5 microinch) or less and retested. At 100% speed near the design point, the ultrapolished blades showed approximately 0.3% to 0.5% increase in adiabatic efficiency. The difference was greater near maximum flow. Due to increased relative measurement error at 60 and 80% speed, the performance difference between the normal and ultrapolished blades was indeterminate at these speeds.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Effect of Ultrapolish on a Transonic Axial Rotor
typeJournal Paper
journal volume135
journal issue1
journal titleJournal of Turbomachinery
identifier doi10.1115/1.4006496
journal fristpage11001
journal lastpage11001
identifier eissn1528-8900
treeJournal of Turbomachinery:;2013:;volume( 135 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)