Show simple item record

contributor authorKhatait, Jitendra P.
contributor authorBrouwer, Dannis M.
contributor authorSoemers, Herman M. J. R.
contributor authorAarts, Ronald G. K. M.
contributor authorHerder, Just L.
date accessioned2017-05-09T01:01:35Z
date available2017-05-09T01:01:35Z
date issued2013
identifier issn1932-6181
identifier othermed_007_03_031004.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/152793
description abstractThe success of flexible instruments in surgery requires high motion and force fidelity and controllability of the tip. However, the friction and the limited stiffness of such instruments limit the motion and force transmission of the instrument. In a previous study, we developed a flexible multibody model of a surgical instrument inside an endoscope in order to study the effect of the friction, bending and rotational stiffness of the instrument and clearance on the motion hysteresis and the force transmission. In this paper, we present the design and evaluation of an experimental setup for the validation of the flexible multibody model and the characterization of the instruments. A modular design was conceived based on three key functionalities: the actuation from the proximal end, the displacement measurement of the distal end, and the measurement of the interaction force. The exactly constrained actuation module achieves independent translation and rotation of the proximal end. The axial displacement and the rotation of the distal end are measured contactless via a specifically designed air bearing guided cam through laser displacement sensors. The errors in the static measurement are 15 خ¼m in translation and 0.15 deg in rotation. Six 1DOF load cell modules using flexures measure the interaction forces and moments with an error of 0.8% and 2.5%, respectively. The achieved specifications allow for the measurement of the characteristic behavior of the instrument inside a curved rigid tube and the validation of the flexible multibody model.
publisherThe American Society of Mechanical Engineers (ASME)
titleDesign of an Experimental Set Up to Study the Behavior of a Flexible Surgical Instrument Inside an Endoscope
typeJournal Paper
journal volume7
journal issue3
journal titleJournal of Medical Devices
identifier doi10.1115/1.4024660
journal fristpage31004
journal lastpage31004
identifier eissn1932-619X
treeJournal of Medical Devices:;2013:;volume( 007 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record