| contributor author | Li, Yufei | |
| contributor author | Wأ¼rgler | |
| contributor author | Schuppisser, Mirjam C. | |
| contributor author | Gerber, Christian | |
| contributor author | Snedeker, Jess G. | |
| date accessioned | 2017-05-09T00:56:36Z | |
| date available | 2017-05-09T00:56:36Z | |
| date issued | 2013 | |
| identifier issn | 0148-0731 | |
| identifier other | bio_135_4_041007.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/151023 | |
| description abstract | The ability to quantify the biomechanical integrity of tendons could provide useful information for both clinical diagnostics and for clinical followup in tracking functional recovery of the injured tissue. This study develops and characterizes a functional endoscopy approach for intraoperative quantification of tendon tear severity using both ex vivo and in vivo experimental models. We first verified the accuracy of endoscopic strain (i.e., tissue stretch) imaging in an ex vivo tear model by comparing endoscopic measurements against gold standard measurements with research grade optics. We then tested in vivo feasibility by endoscopically quantifying altered tissue strain distributions in a rat supraspinatus model of partial tendon tear. The endoscopic method was able to achieve diagnostically relevant levels of accuracy compared to research grade optics (mean error = 26.2 آ±â€‰19.1%), and tissue strain analysis could sensitively discern torn tendon subregions. Applying this approach to freehand in vivo endoscopic strain measurements, we were similarly able to discern functional changes in partially torn tendons (average maximum principal strains surrounding the lesion: 5.1 آ±â€‰2.9% versus intact controls: 1.9 آ±â€‰1.4%; p = 0.023). These findings indicate that the functional endoscopic assessment of tendon mechanical integrity is not only possible but could potentially offer intraoperative arthroscopic guidance for management of tendon tears in man. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Endoscopic Functional Imaging of Partial Tendon Tears—Proof of Concept and Intraoperative Feasibility | |
| type | Journal Paper | |
| journal volume | 135 | |
| journal issue | 4 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.4023702 | |
| journal fristpage | 41007 | |
| journal lastpage | 41007 | |
| identifier eissn | 1528-8951 | |
| tree | Journal of Biomechanical Engineering:;2013:;volume( 135 ):;issue: 004 | |
| contenttype | Fulltext | |