Show simple item record

contributor authorFernandez, Michael
contributor authorVink, Joy
contributor authorYoshida, Kyoko
contributor authorWapner, Ronald
contributor authorMyers, Kristin M.
date accessioned2017-05-09T00:56:32Z
date available2017-05-09T00:56:32Z
date issued2013
identifier issn0148-0731
identifier otherbio_135_2_021024.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/151002
description abstractThe mechanical integrity of the uterine cervix is critical for a pregnancy to successfully reach full term. It must be strong to retain the fetus throughout gestation and then undergo a remodeling and softening process before labor for delivery of the fetus. It is believed that cervical insufficiency (CI), a condition in pregnancy resulting in preterm birth (PTB), is related to a cervix with compromised mechanical strength which cannot resist deformation caused by external forces generated by the growing fetus. Such PTBs are responsible for infant developmental problems and in severe cases infant mortality. To understand the etiologies of CI, our overall research goal is to investigate the mechanical behavior of the cervix. Permeability is a mechanical property of hydrated collagenous tissues that dictates the timedependent response of the tissue to mechanical loading. The goal of this study was to design a novel soft tissue permeability testing device and to present direct hydraulic permeability measurements of excised nonpregnant (NP) and pregnant (PG) human cervical tissue from women with different obstetric histories. Results of hydraulic permeability testing indicate repeatability for specimens from single patients, with an order of magnitude separating the NP and PG group means (2.1 آ±â€ƒ1.4أ—1014 and 3.2 آ±â€ƒ4.8أ—1013m4/Nآ·s, respectively), and large variability within the NP and PG sample groups. Differences were found between samples with similar obstetric histories, supporting the view that medical history may not be a good predictor of permeability (and therefore mechanical behavior) and highlighting the need for patientspecific measurements of cervical mechanical properties. The permeability measurements from this study will be used in future work to model the constitutive material behavior of cervical tissue and to develop in vivo diagnostic tools to stage the progression of labor.
publisherThe American Society of Mechanical Engineers (ASME)
titleDirect Measurement of the Permeability of Human Cervical Tissue
typeJournal Paper
journal volume135
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4023380
journal fristpage21024
journal lastpage21024
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2013:;volume( 135 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)