Show simple item record

contributor authorM. Kazemi
contributor authorM. D. Buschmann
contributor authorP. Savard
contributor authorL. P. Li
date accessioned2017-05-09T00:48:35Z
date available2017-05-09T00:48:35Z
date copyrightFebruary, 2012
date issued2012
identifier issn0148-0731
identifier otherJBENDY-28990#021001_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148283
description abstractPartial meniscectomy is believed to change the biomechanics of the knee joint through alterations in the contact of articular cartilages and menisci. Although fluid pressure plays an important role in the load support mechanism of the knee, the fluid pressurization in the cartilages and menisci has been ignored in the finite element studies of the mechanics of meniscectomy. In the present study, a 3D fibril-reinforced poromechanical model of the knee joint was used to explore the fluid flow dependent changes in articular cartilage following partial medial and lateral meniscectomies. Six partial longitudinal meniscectomies were considered under relaxation, simple creep, and combined creep loading conditions. In comparison to the intact knee, partial meniscectomy not only caused a substantial increase in the maximum fluid pressure but also shifted the location of this pressure in the femoral cartilage. Furthermore, these changes were positively correlated to the size of meniscal resection. While in the intact joint, the location of the maximum fluid pressure was dependent on the loading conditions, in the meniscectomized joint the location was predominantly determined by the site of meniscal resection. The partial meniscectomy also reduced the rate of the pressure dissipation, resulting in even larger difference between creep and relaxation times as compared to the case of the intact knee. The knee joint became stiffer after meniscectomy because of higher fluid pressure at knee compression followed by slower pressure dissipation. The present study indicated the role of fluid pressurization in the altered mechanics of meniscectomized knees.
publisherThe American Society of Mechanical Engineers (ASME)
titlePartial Meniscectomy Changes Fluid Pressurization in Articular Cartilage in Human Knees
typeJournal Paper
journal volume134
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4005764
journal fristpage21001
identifier eissn1528-8951
keywordsPressure
keywordsFluid pressure
keywordsCreep
keywordsFluids
keywordsRelaxation (Physics)
keywordsStress
keywordsCartilage
keywordsKnee
keywordsBiological tissues
keywordsModeling
keywordsHigh pressure (Physics) AND Finite element analysis
treeJournal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record