Show simple item record

contributor authorNicholas Dutcheshen
contributor authorTristan Maerz
contributor authorPatrick Rabban
contributor authorRoger C. Haut
contributor authorKeith D. Button
contributor authorKevin C. Baker
contributor authorJoseph Guettler
date accessioned2017-05-09T00:48:25Z
date available2017-05-09T00:48:25Z
date copyrightAugust, 2012
date issued2012
identifier issn0148-0731
identifier otherJBENDY-29000#081007_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148224
description abstractRadio frequency energy (RFE) thermal chondroplasty has been a widely-utilized method of cartilage debridement in the past. Little is known regarding its effect on tissue mechanics. This study investigated the acute biomechanical effects of bipolar RFE treatment on human chondromalacic cartilage. Articular cartilage specimens were extracted (n = 50) from femoral condyle samples of patients undergoing total knee arthroplasty. Chondromalacia was graded with the Outerbridge classification system. Tissue thicknesses were measured using a needle punch test. Specimens underwent pretreatment load-relaxation testing using a spherical indenter. Bipolar RFE treatment was applied for 45 s and the indentation protocol was repeated. Structural properties were derived from the force-time data. Mechanical properties were derived using a fibril-reinforced biphasic cartilage model. Statistics were performed using repeated measures ANOVA. Cartilage thickness decreased after RFE treatment from a mean of 2.61 mm to 2.20 mm in Grade II, II-III, and III specimens (P < 0.001 each). Peak force increased after RFE treatment from a mean of 3.91 N to 4.91 N in Grade II and III specimens (P = 0.002 and P = 0.003, respectively). Equilibrium force increased after RFE treatment from a mean of 0.236 N to 0.457 N (P < 0.001 each grade). Time constant decreased after RFE treatment from a mean of 0.392 to 0.234 (P < 0.001 for each grade). Matrix modulus increased in all specimens following RFE treatment from a mean 259.12 kPa to 523.36 kPa (P < 0.001 each grade). Collagen fibril modulus decreased in Grade II and II-III specimens from 60.50 MPa to 42.04 MPa (P < 0.001 and P = 0.005, respectively). Tissue permeability decreased in Grade II and III specimens from 2.04 *10−15 m4 /Ns to 0.91 *10−15 m4 /Ns (P < 0.001 and P = 0.009, respectively). RFE treatment decreased thickness, time constant, fibril modulus, permeability, but increased peak force, equilibrium force, and matrix modulus. While resistance to shear and tension could be compromised due to removal of the superficial layer and decreased fibril modulus, RFE treatment increases matrix modulus and decreases tissue permeability which may restore the load- bearing capacity of the cartilage.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Acute Effect of Bipolar Radiofrequency Energy Thermal Chondroplasty on Intrinsic Biomechanical Properties and Thickness of Chondromalacic Human Articular Cartilage
typeJournal Paper
journal volume134
journal issue8
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4007105
journal fristpage81007
identifier eissn1528-8951
keywordsBiological tissues
keywordsThickness
keywordsCartilage
keywordsBiomechanics
keywordsPermeability AND Force
treeJournal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record