Show simple item record

contributor authorAli Vahdati
contributor authorYang Zhao
contributor authorTimothy C. Ovaert
contributor authorDiane R. Wagner
date accessioned2017-05-09T00:48:19Z
date available2017-05-09T00:48:19Z
date copyrightNovember, 2012
date issued2012
identifier issn0148-0731
identifier otherJBENDY-926471#111004_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148184
description abstractScaffold-based tissue-engineered constructs as well as cell-free implants offer promising solutions to focal cartilage lesions. However, adequate mechanical stability of these implants in the lesion is required for successful repair. Fibrin is the most common clinically available adhesive for cartilage implant fixation, but fixation quality using fibrin is not well understood. The objectives of this study were to investigate the conditions leading to damage in the fibrin adhesive and to determine which adhesive properties are important in preventing delamination at the interface. An idealized finite element model of the medial compartment of the knee was created, including a circular defect and an osteochondral implant. Damage and failure of fibrin at the interface was represented by a cohesive zone model with coefficients determined from an inverse finite element method and previously published experimental data. Our results demonstrated that fibrin glue alone may not be strong enough to withstand physiologic loads in vivo while fibrin glue combined with chondrocytes more effectively prevents damage at the interface. The results of this study suggest that fibrin fails mainly in shear during off-axis loading and that adhesive materials that are stronger or more compliant than fibrin may be good alternatives due to decreased failure at the interface. The present model may be used to improve design and testing protocols of bioadhesives and give insight into the failure mechanisms of cartilage implant fixation in the knee joint.
publisherThe American Society of Mechanical Engineers (ASME)
titleComputational Investigation of Fibrin Mechanical and Damage Properties at the Interface Between Native Cartilage and Implant
typeJournal Paper
journal volume134
journal issue11
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4007748
journal fristpage111004
identifier eissn1528-8951
keywordsAdhesives
keywordsGlues
keywordsCartilage
keywordsKnee
keywordsStress
keywordsFailure
keywordsShear (Mechanics)
keywordsChondrocytes
keywordsBiological tissues AND Finite element model
treeJournal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record