Show simple item record

contributor authorMyung Hyun Kim
contributor authorMin Sung Chun
contributor authorWha Soo Kim
contributor authorJang Ho Yoon
contributor authorMin Soo Kim
contributor authorHang Sub Urm
contributor authorByung Jae Noh
contributor authorYong Suk Suh
contributor authorYoon Pyo Kil
contributor authorJae Myung Lee
date accessioned2017-05-09T00:46:25Z
date available2017-05-09T00:46:25Z
date copyrightNovember, 2011
date issued2011
identifier issn0892-7219
identifier otherJMOEEX-28383#041401_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/147347
description abstractThe objective of this study is to investigate the typical failure mode and to obtain the stress range versus number of cycles to failure (S-N) data of MARK-III type liquefied natural gas (LNG) insulation system under the fatigue loading at actual cryogenic environment. A systematic experimental research is carried out for the assessment of the fatigue strength of MARK-III insulation system at cryogenic temperature. Three different types of test specimens are tested for the evaluation of fatigue performance of MARK-III insulation system. Test specimens are determined considering the fatigue vulnerable locations such as mastic area, slit area, and top bridge pad area inside the actual LNG cargo tanks. All test specimens are fabricated as close as possible to the actual yard practice. A series of fatigue test results is represented as S-N curves. Cyclic fatigue loadings were carefully considered similar to the actual sloshing loads. The effect of sloshing impacts is considered by selecting the stress ratio (R=−10). The load levels have been determined based on the ultimate strength of reinforced polyurethane foam as 12.2 bars. Different cryogenic temperatures are employed according to the test locations in consideration of temperature gradient within the insulation system. All test results including fatigue life, as well as failure locations of MARK-III insulation system at cryogenic temperatures, are reported and compared with those at room temperature. Consistent S-N curves of MARK-III insulation system at both room and cryogenic temperatures are obtained and compared. The slopes of S-N curves from both fatigue test results are observed to be almost identical, and the fatigue strengths are found to exhibit similar trend. The results from this research can be used for the fatigue assessment of the LNGC insulation system, as well as a design guideline of LNG CCS at cryogenic temperature.
publisherThe American Society of Mechanical Engineers (ASME)
titleCryogenic Fatigue Strength Assessment for MARK-III Insulation System of LNG Carriers
typeJournal Paper
journal volume133
journal issue4
journal titleJournal of Offshore Mechanics and Arctic Engineering
identifier doi10.1115/1.4003389
journal fristpage41401
identifier eissn1528-896X
keywordsFatigue
keywordsTemperature
keywordsStress
keywordsFatigue strength
keywordsFatigue testing
keywordsInsulation
keywordsFailure
keywordsLiquefied natural gas
keywordsCycles
keywordsSloshing
keywordsPressure AND Fatigue life
treeJournal of Offshore Mechanics and Arctic Engineering:;2011:;volume( 133 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record