Show simple item record

contributor authorH. C. R. Reuter
contributor authorD. G. Kröger
date accessioned2017-05-09T00:44:14Z
date available2017-05-09T00:44:14Z
date copyrightAugust, 2011
date issued2011
identifier issn0098-2202
identifier otherJFEGA4-27482#081104_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/146295
description abstractCooling tower inlet losses are the flow losses or viscous dissipation of mechanical energy affected directly by the cooling tower inlet design, which according to the counterflow natural draft wet-cooling tower performance analysis example given in Kröger (Kröger, 2004, Air-Cooled Heat Exchangers and Cooling Towers: Thermal-Flow Performance Evaluation, Pennwell Corp., Tulsa, OK), can be more than 20% of the total cooling tower flow losses. Flow separation at the lower edge of the shell results in a vena contracta with a distorted inlet velocity distribution that causes a reduction in effective fill or heat exchanger flow area. In this paper, a two-dimensional (axi-symmetric) computational fluid dynamic (CFD) model is developed using the commercial CFD code ANSYS FLUENT, to simulate the flow patterns, loss coefficients and effective flow diameter of circular natural draft cooling tower inlets under windless conditions. The CFD results are compared with axial velocity profile data, tower inlet loss coefficients and effective diameters determined experimentally by Terblanche (Terblanche, 1993, “Inlaatverliese by Koeltorings,” M. Sc. Eng. thesis, Stellenbosch University, Stellenbosch, South Africa) on a cylindrical scale sector model as well as applicable empirical relations found in Kröger, determined using the same experimental apparatus as Terblanche. The validated CFD model is used to investigate the effects of Reynolds number, shell-wall thickness, shell wall inclination angle, fill loss coefficient, fill type, inlet diameter to inlet height ratio and inlet geometry on the flow patterns, inlet loss coefficient and effective diameter of full-scale cooling towers. Ultimately, simple correlations are proposed for determining the cooling tower inlet loss coefficient and inlet effective flow diameter ratio of full-scale cooling towers excluding the effect of rain zones and the structural supports around the cooling tower entrance.
publisherThe American Society of Mechanical Engineers (ASME)
titleComputational Fluid Dynamics Analysis of Cooling Tower Inlets
typeJournal Paper
journal volume133
journal issue8
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.4004454
journal fristpage81104
identifier eissn1528-901X
keywordsComputational fluid dynamics
keywordsCooling towers
keywordsFlow (Dynamics) AND Electrical resistance
treeJournal of Fluids Engineering:;2011:;volume( 133 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record