Show simple item record

contributor authorJoseph T. Keyes
contributor authorDongmei Yan
contributor authorUrs Utzinger
contributor authorJonathan P. Vande Geest
contributor authorJacob H. Rader
date accessioned2017-05-09T00:42:21Z
date available2017-05-09T00:42:21Z
date copyrightSeptember, 2011
date issued2011
identifier issn0148-0731
identifier otherJBENDY-27218#095001_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/145375
description abstractThe biomechanical model of glaucoma considers intraocular pressure-related stress and resultant strain on load bearing connective tissues of the optic nerve and surrounding peripapillary sclera as one major causative influence that effects cellular, vascular, and axonal components of the optic nerve. By this reasoning, the quantification of variations in the microstructural architecture and macromechanical response of scleral shells in glaucomatous compared to healthy populations provides an insight into any variations that exist between patient populations. While scleral shells have been tested mechanically in planar and pressure-inflation scenarios the link between the macroscopic biomechanical response and the underlying microstructure has not been determined to date. A potential roadblock to determining how the microstructure changes based on pressure is the ability to mount the spherical scleral shells in a method that does not induce unwanted stresses to the samples (for instance, in the flattening of the spherical specimens), and then capturing macroscopic and microscopic changes under pressure. Often what is done is a macroscopic test followed by sample fixation and then imaging to determine microstructural organization. We introduce a novel device and method, which allows spherical samples to be pressurized and macroscopic and microstructural behavior quantified on fully hydrated ocular specimens. The samples are pressurized and a series of markers on the surface of the sclera imaged from several different perspectives and reconstructed between pressure points to allow for mapping of nonhomogenous strain. Pictures are taken from different perspectives through the use of mounting the pressurization scheme in a gimbal that allows for positioning the sample in several different spherical coordinate system configurations. This ability to move the sclera in space about the center of the globe, coupled with an upright multiphoton microscope, allows for collecting collagen, and elastin signal in a rapid automated fashion so the entire globe can be imaged.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Gimbal-Mounted Pressurization Chamber for Macroscopic and Microscopic Assessment of Ocular Tissues
typeJournal Paper
journal volume133
journal issue9
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4004921
journal fristpage95001
identifier eissn1528-8951
keywordsBiomechanics
keywordsBiological tissues
keywordsTesting
keywordsPressure
keywordsImaging
keywordsMicroscopes
keywordsShells
keywordsStress AND Rotation
treeJournal of Biomechanical Engineering:;2011:;volume( 133 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record