Show simple item record

contributor authorJ. Q. Choo
contributor authorD. P. C. Lau
contributor authorC. K. Chui
contributor authorT. Yang
contributor authorC. B. Chng
contributor authorS. H. Teoh
date accessioned2017-05-09T00:36:35Z
date available2017-05-09T00:36:35Z
date copyrightJune, 2010
date issued2010
identifier issn0148-0731
identifier otherJBENDY-27144#065001_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142598
description abstractMechanical and computational models consisting of flow channels with convergent and oscillating constrictions have been applied to study the dynamics of human vocal fold vibration. To the best of our knowledge, no mechanical model has been studied using a material substitute with similar physical properties to the human vocal fold for surgical experimentation. In this study, we design and develop a mechanical larynx with agarose as a vocal fold substitute, and assess its suitability for surgical experimentation. Agarose is selected as a substitute for the vocal fold as it exhibits similar nonlinear hyperelastic characteristics to biological soft tissue. Through uniaxial compression and extension tests, we determined that agarose of 0.375% concentration most closely resembles the vocal fold mucosa and ligament of a 20-year old male for small tensile strain with an R2 value of 0.9634 and root mean square error of 344.05±39.84 Pa. Incisions of 10 mm lengthwise and 3 mm in depth were created parallel to the medial edge on the superior surface of agar phantom. These were subjected to vibrations of 80, 130, and 180 Hz, at constant amplitude of 0.9 mm over a period of 10 min each in the mechanical larynx model. Lateral expansion of the incision was observed to be most significant for the lower frequency of 80 Hz. This model serves as a basis for future assessments of wound closure techniques during microsurgery to the vocal fold.
publisherThe American Society of Mechanical Engineers (ASME)
titleDesign of a Mechanical Larynx With Agarose as a Soft Tissue Substitute for Vocal Fold Applications
typeJournal Paper
journal volume132
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4001161
journal fristpage65001
identifier eissn1528-8951
keywordsAgar
keywordsVocal cords
keywordsStress AND Phantoms
treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 006
contenttypeFulltext