Show simple item record

contributor authorMack G. Gardner-Morse
contributor authorNelson J. Tacy
contributor authorBruce D. Beynnon
contributor authorMaria L. Roemhildt
date accessioned2017-05-09T00:36:30Z
date available2017-05-09T00:36:30Z
date copyrightSeptember, 2010
date issued2010
identifier issn0148-0731
identifier otherJBENDY-27166#094502_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142561
description abstractAlterations to joint tissues, including subchondral bone, occur with osteoarthritis. A microindentation technique was developed to determine the local compressive modulus of subchondral bone. This test, in conjunction with a cartilage indentation test at the same location, could evaluate changes of these material properties in both tissues. The accuracy of the technique was determined by applying it to materials of known moduli. The technique was then applied to rat tibial plateaus to characterize the local moduli of the subchondral bone. An established nanoindentation method was adopted to determine the modulus of subchondral bone following penetration of the overlying articular cartilage. Three cycles of repeated loadings were applied (2.452 N, 30 s hold). The slope of the load-displacement response during the unloading portion of the third cycle was used to measure the stiffness. Indentation tests were performed on two polyurethane foams and polymethyl-methacrylate for validation (n=15). Regression analysis was used to compare the moduli with reference values. Subchondral bone moduli of tibial plateaus from Sprague-Dawley rats (n=5) were measured for central and posterior locations of medial and lateral compartments. An analysis of variance was used to analyze the effects of compartment and test location. The measured moduli of the validation materials correlated with the reference values (R2=0.993, p=0.05). In rat tibial plateaus, the modulus of the posterior location was significantly greater than the center location (4.03±1.00 GPa and 3.35±1.16 GPa respectively, p=0.03). The medial compartment was not different from the lateral compartment. This method for measuring the subchondral bone in the same location as articular cartilage allows studies of the changes in these material properties with the onset and progression of osteoarthritis.
publisherThe American Society of Mechanical Engineers (ASME)
titleIn Situ Microindentation for Determining Local Subchondral Bone Compressive Modulus
typeJournal Paper
journal volume132
journal issue9
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4001872
journal fristpage94502
identifier eissn1528-8951
keywordsBone
keywordsCartilage
keywordsStress
keywordsMaterials properties
keywordsDisplacement AND Stiffness
treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record