Show simple item record

contributor authorChander Sadasivan
contributor authorBaruch B. Lieber
date accessioned2017-05-09T00:34:39Z
date available2017-05-09T00:34:39Z
date copyrightDecember, 2009
date issued2009
identifier issn1932-6181
identifier otherJMDOA4-28008#041005_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141522
description abstractThe long-term outcome of endovascular coiling of cerebral aneurysms is directly related to the packing density at the time of treatment. In general, the highest packing density achievable is only about 45% due to the quasirandom distribution of currently available coils within aneurysms. We investigated whether packing densities could be maximized via more ordered coil configurations. Three different coil configurations—circular loops, planar spirals, and spherical helices—were investigated. The packing densities achievable in maximally filling the volume of an exemplar human basilar aneurysm with each coil configuration were calculated numerically. Coil packing simulations were also carried out for aneurysms idealized as spheres over diameters ranging from 2 mm to 30 mm. The packing densities with the loop, spiral, and spherical helix configurations were 82%, 60%, and 73%, respectively, for the human aneurysm model; the numbers of coils required were 693, 34, and 13, respectively. Simulations within idealized aneurysms suggest that aneurysms cannot be packed to more than 91% with coils of constant circular cross section. The spherical helix configuration provides a constant packing density (coefficient of variation of 0.4%) over the range of aneurysm diameters studied as compared to the two other configurations (coefficients of variation of 9% and 8%). Coil configurations that allow for ordered filling of cerebral aneurysms can potentially provide packing densities that are twice those currently achieved. The spherical helix configuration seems to be the most technically feasible and stable configuration of the three coil types investigated.
publisherThe American Society of Mechanical Engineers (ASME)
titleNumerical Investigation of Coil Configurations That Provide Ultrahigh Packing Density of Saccular Aneurysms
typeJournal Paper
journal volume3
journal issue4
journal titleJournal of Medical Devices
identifier doi10.1115/1.4000453
journal fristpage41005
identifier eissn1932-619X
treeJournal of Medical Devices:;2009:;volume( 003 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record