Show simple item record

contributor authorAsher L. Trager
contributor authorJaehoon Seong
contributor authorBaruch B. Lieber
contributor authorChander Sadasivan
date accessioned2017-05-09T00:31:48Z
date available2017-05-09T00:31:48Z
date copyrightMarch, 2009
date issued2009
identifier issn0148-0731
identifier otherJBENDY-26901#034506_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/140009
description abstractThe rupture of a cerebral aneurysm can result in a hemorrhagic stroke. A flow diverter, which is a porous tubular mesh, can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. By finding a correlation between particle image velocimetry (PIV) and digital subtraction angiography, a better assessment of how well an aneurysm is excluded from the parent artery can be made in the clinical setting. A model of a rabbit elastase-induced aneurysm was connected to a mock circulation loop. The model was then placed under angiography. Recorded angiograms were analyzed so that a contrast concentration-time curve based on the average grayscale intensity inside the aneurysm could be determined. That curve was then fitted to a mathematical model that quantifies the influence of convection and diffusion on contrast transport. Optimized parameters were correlated with the intraneurysmal mean kinetic energy measured by PIV in the same aneurysm model. A strong correlation was observed between the convection and diffusion time constants and the mean kinetic energy inside the aneurysm. Analyzing the flow of angiographic contrast into and out of the aneurysm after implantation of a flow diverter allows for prediction of the efficacy of the device in excluding the aneurysm. Correlating hydrodynamic measures obtained by angiography to those obtained by detailed techniques such as PIV increases confidence in such predictions.
publisherThe American Society of Mechanical Engineers (ASME)
titleCorrelation Between Angiographic and Particle Image Velocimetry Quantifications of Flow Diverters in an In Vitro Model of Elastase-Induced Rabbit Aneurysms
typeJournal Paper
journal volume131
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3049528
journal fristpage34506
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsParticulate matter
keywordsKinetic energy
keywordsAneurysms
keywordsConvection AND Diffusion (Physics)
treeJournal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)