Show simple item record

contributor authorJames C. Iatridis
contributor authorMasaru Furukawa
contributor authorJeffrey P. Laible
contributor authorIan A. F. Stokes
contributor authorMack G. Gardner-Morse
date accessioned2017-05-09T00:31:47Z
date available2017-05-09T00:31:47Z
date copyrightMarch, 2009
date issued2009
identifier issn0148-0731
identifier otherJBENDY-26901#031006_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139996
description abstractIntervertebral disk degeneration results in alterations in the mechanical, chemical, and electrical properties of the disk tissue. The purpose of this study is to record spatially resolved streaming potential measurements across intervertebral disks exposed to cyclic compressive loading. We hypothesize that the streaming potential profile across the disk will vary with radial position and frequency and is proportional to applied load amplitude, according to the presumed fluid-solid relative velocity and measured glycosaminoglycan content. Needle electrodes were fabricated using a linear array of Ag∕AgCl micro-electrodes and inserted into human motion segments in the midline from anterior to posterior. They were connected to an amplifier to measure electrode potentials relative to the saline bath ground. Motion segments were loaded in axial compression under a preload of 500N, sinusoidal amplitudes of ±200N and ±400N, and frequencies of 0.01Hz, 0.1Hz, and 1Hz. Streaming potential data were normalized by applied force amplitude, and also compared with paired experimental measurements of glycosaminoglycans in each disk. Normalized streaming potentials varied significantly with sagittal position and there was a significant location difference at the different frequencies. Normalized streaming potential was largest in the central nucleus region at frequencies of 0.1Hz and 1.0Hz with values of approximately 3.5μV∕N. Under 0.01Hz loading, normalized streaming potential was largest in the outer annulus regions with a maximum value of 3.0μV∕N. Correlations between streaming potential and glycosaminoglycan content were significant, with R2 ranging from 0.5 to 0.8. Phasic relationships between applied force and electrical potential did not differ significantly by disk region or frequency, although the largest phase angles were observed at the outermost electrodes. Normalized streaming potentials were associated with glycosaminoglycan content, fluid, and ion transport. Results suggested that at higher frequencies the transport of water and ions in the central nucleus region may be larger, while at lower frequencies there is enhanced transport near the periphery of the annulus. This study provides data that will be helpful to validate multiphasic models of the disk.
publisherThe American Society of Mechanical Engineers (ASME)
titleSpatially Resolved Streaming Potentials of Human Intervertebral Disk Motion Segments Under Dynamic Axial Compression
typeJournal Paper
journal volume131
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3005164
journal fristpage31006
identifier eissn1528-8951
keywordsMotion
keywordsStress
keywordsElectrodes
keywordsDisks
keywordsCompression
keywordsIntervertebral discs
keywordsFluids
keywordsFrequency
keywordsElectric potential
keywordsPermeability
keywordsBiological tissues
keywordsAnnulus
keywordsMeasurement
keywordsneedles
keywordsForce
keywordsWater AND Fluid dynamics
treeJournal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record