Show simple item record

contributor authorLiam T. Breen
contributor authorBruce P. Murphy
contributor authorPeter E. McHugh
date accessioned2017-05-09T00:31:33Z
date available2017-05-09T00:31:33Z
date copyrightAugust, 2009
date issued2009
identifier issn0148-0731
identifier otherJBENDY-27015#081001_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139871
description abstractOver the past 25 years, many laboratory based bioreactors have been used to study the cellular response to hemodynamic forces. The vast majority of these studies have focused on the effect of a single isolated hemodynamic force, generally consisting of a wall shear stress (WSS) or a tensile hoop strain (THS). However, investigating the cellular response to a single isolated force does not accurately represent the true in vivo situation, where a number of forces are acting simultaneously. This study used a novel bioreactor to investigate the cellular response of human umbilical vein endothelial cells (HUVECs) exposed to a combination of steady WSS and a range of cyclic THS. HUVECs exposed to a range of cyclic THS (0–12%), over a 12 h testing period, expressed an upregulation of both ICAM-1 and VCAM-1. HUVECs exposed to a steady WSS (0 dynes/cm2 and 25 dynes/cm2), over a 12 h testing period, also exhibited an ICAM-1 upregulation but a VCAM-1 downregulation, where the greatest level of WSS stimulus resulted in the largest upregulation and downregulation of ICAM-1 and VCAM-1, respectively. A number of HUVEC samples were exposed to a high steady WSS (25 dynes/cm2) combined with a range of cyclic THS (0–4%, 0–8%, and 0–12%) for a 12 h testing period. The initial ICAM-1 upregulation, due to the WSS alone, was downregulated with the addition of a cyclic THS. It was observed that the largest THS (0–12%) had the greatest reducing effect on the ICAM-1 upregulation. Similarly, the initial VCAM-1 downregulation, due to the high steady WSS alone, was further downregulated with the addition of a cyclic THS. A similar outcome was observed when HUVEC samples were exposed to a low steady WSS combined with a range of cyclic THS. However, the addition of a THS to the low WSS did not result in an expected ICAM-1 downregulation. In fact, it resulted in a trend of unexpected ICAM-1 upregulation. The unexpected cellular response to the combination of a steady WSS and a cyclic THS demonstrates that such a response could not be determined by simply superimposing the cellular responses exhibited by ECs exposed to a steady WSS and a cyclic THS that were applied in isolation.
publisherThe American Society of Mechanical Engineers (ASME)
titleMulti-Axial Mechanical Stimulation of HUVECs Demonstrates That Combined Loading is not Equivalent to the Superposition of Individual Wall Shear Stress and Tensile Hoop Stress Components
typeJournal Paper
journal volume131
journal issue8
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3127248
journal fristpage81001
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsBioreactors
keywordsTesting
keywordsStress AND Shear (Mechanics)
treeJournal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record