Show simple item record

contributor authorZhaoming He
contributor authorWei Sun
contributor authorBo Gao
contributor authorShamik Bhattacharya
contributor authorTyler Harrist
contributor authorSibi Mathew
date accessioned2017-05-09T00:31:29Z
date available2017-05-09T00:31:29Z
date copyrightNovember, 2009
date issued2009
identifier issn0148-0731
identifier otherJBENDY-27068#111012_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139827
description abstractMitral valve edge-to-edge repair (ETER) alters valve mechanics, which may impact efficacy and durability of the repair. The objective of this paper was to quantify stretches in the central region of the anterior leaflet of the mitral valve after ETER with a single suture and 6 mm suture. Sixteen markers, forming a 4×4 array, were attached onto the central region of the mitral valve anterior leaflet. The mitral valve was subjected to ETER with a single suture and 6 mm suture, and mounted in an in vitro flow loop simulating physiological conditions. Images of the marker array were used to calculate marker displacement and stretch. A total of 9 mitral valves were tested. Two peak stretches were observed during a cardiac cycle, one in systole and the other in diastole under mitral valve edge-to-edge repair condition. The major principal (radial) stretch during systole was significantly greater than that during diastole. However, there was no significant difference between the minor principal (circumferential) stretch during diastole and that during systole. In addition, there were no significant differences in the radial and circumferential, or areal stretches and stretch rates during diastole between the single suture and 6 mm suture. The ETER subjects the mitral valve leaflets to double frequency of loading and unloading. Minor change in suture length may not result in a significant load difference in the central region of the anterior leaflet during diastole.
publisherThe American Society of Mechanical Engineers (ASME)
titleIn Vitro Stretches of the Mitral Valve Anterior Leaflet Under Edge-to-Edge Repair Condition
typeJournal Paper
journal volume131
journal issue11
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4000111
journal fristpage111012
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsMaintenance
keywordsStress
keywordsValves
keywordsCycles AND Durability
treeJournal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record