Show simple item record

contributor authorAlbert H. Vette
contributor authorEgor Sanin
contributor authorAbdulkadir Bulsen
contributor authorKei Masani
contributor authorMilos R. Popovic
contributor authorAlan Morris
date accessioned2017-05-09T00:29:53Z
date available2017-05-09T00:29:53Z
date copyrightDecember, 2008
date issued2008
identifier issn1932-6181
identifier otherJMDOA4-27997#041007_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/138994
description abstractTo date, a postural perturbation system capable of generating position-, velocity-, and force-controlled perturbations while being portable and suitable for use during various postural scenarios does not exist. Therefore, the purpose of the present study was to design, develop, and test a portable and automated postural perturbation system (PAPPS) that can be used to measure and train postural reactions during sitting, standing, and treadmill walking. The core component of the PAPPS was a linear actuator that provides horizontal perturbations. The actuator could generate arbitrary displacement, velocity, or force perturbations as a function of time. In addition, the PAPPS was able to measure the actuator’s displacement, velocity, and load, which could be used to study postural perturbation responses. The height at which the PAPPS was delivering the perturbations could be easily adjusted to allow for different subject/patient anthropometrics and a wide range of postural scenarios such as sitting, standing, and treadmill walking. The PAPPS generated a peak displacement of 0.6m, a peak velocity of 0.5m∕s, and a peak force of 600N, which is more than sufficient to elicit high intensity postural perturbations. Multiple and nested safety circuits have been implemented into the PAPPS to ensure the safety of the subjects/patients during experiments and/or training. To evaluate the accuracy and repeatability of the PAPPS during position-, velocity-, and force-controlled perturbations, experiments were conducted using sinusoidal, impulse, and ramp profiles as a function of time. Highly sensitive displacement and force sensors that were external to the PAPPS were used to determine the accuracy and repeatability of the proposed device. In addition, a case study was performed to demonstrate the performance of the PAPPS during pseudorandom sinusoidal perturbations that were applied to a healthy individual during sitting. The accuracy and repeatability tests suggest that the PAPPS can generate reliable and high-precision displacement, velocity, and force perturbations. Potential applications of this system include, but are not limited to (1) studies of postural response to various perturbation types and profiles in diverse subject populations during sitting, standing, and treadmill walking, and (2) training of postural balance in diverse patient populations during sitting, standing, and treadmill walking.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Portable and Automated Postural Perturbation System for Balance Assessment, Training, and Neuromuscular System Identification
typeJournal Paper
journal volume2
journal issue4
journal titleJournal of Medical Devices
identifier doi10.1115/1.3026558
journal fristpage41007
identifier eissn1932-619X
keywordsForce
keywordsStress
keywordsActuators
keywordsDisplacement
keywordsCircuits AND Design
treeJournal of Medical Devices:;2008:;volume( 002 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record