Show simple item record

contributor authorP. R. Ouyang
contributor authorW. J. Zhang
contributor authorM. M. Gupta
date accessioned2017-05-09T00:29:35Z
date available2017-05-09T00:29:35Z
date copyrightOctober, 2008
date issued2008
identifier issn1050-0472
identifier otherJMDEDB-27884#104501_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/138832
description abstractA mechanical amplifier is an important device, which together with a piezoelectric actuator can achieve motion with high resolution and long range. In this paper, a new topology based on a symmetric five-bar structure for displacement amplification is proposed, and a compliant mechanism is implemented for the amplifier. In short, the new mechanical amplifier is called a compliant mechanical amplifier (CMA). The proposed CMA can achieve large amplification ratio and high natural frequency, as opposed to the existing CMAs, in terms of topology. Detailed analysis with finite element method has further shown that a double symmetric beam five-bar structure using corner-filleted hinges can provide good performances compared with its counterpart, which is based on four-bar topology. Finally, experiments are conducted to give some validation of the theoretical analysis.
publisherThe American Society of Mechanical Engineers (ASME)
titleA New Compliant Mechanical Amplifier Based on a Symmetric Five-Bar Topology
typeJournal Paper
journal volume130
journal issue10
journal titleJournal of Mechanical Design
identifier doi10.1115/1.2965600
journal fristpage104501
identifier eissn1528-9001
treeJournal of Mechanical Design:;2008:;volume( 130 ):;issue: 010
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record