Show simple item record

contributor authorX. B. Chen
contributor authorM. G. Li
contributor authorH. Ke
date accessioned2017-05-09T00:29:27Z
date available2017-05-09T00:29:27Z
date copyrightApril, 2008
date issued2008
identifier issn1087-1357
identifier otherJMSEFK-28027#021003_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/138746
description abstractMade from biomaterials, tissue scaffolds are three-dimensional (3D) constructs with highly interconnected pore networks for facilitating cell growth and flow transport of nutrients and metabolic waste. To fabricate the scaffolds with complex structures, dispensing-based rapid prototyping technique has been employed recently. In such a fabrication process, the flow rate of biomaterial dispensed is of importance since it directly contributes to the pore size and porosity of the scaffold fabricated. However, the modeling of the flow rate has proven to be a challenging task due to its complexity. This paper presents the development of a model for the flow rate in the scaffold fabrication process based on the fundamentals of fluid mechanics. To verify the effectiveness of the developed model, experiments were carried out, in which the chitosan solution (2% w/v) in acetic acid was used for dispensing under different applied pressures (50kPa, 100kPa, 150kPa, 200kPa, and 250kPa) and needle heater temperatures (25°C, 35°C, 50°C, and 65°C). The measured flow rates were used to identify the flow behavior of the solution and were compared to the predictions from the developed model to illustrate the model effectiveness. Based on the developed model, simulations were carried out to identify the effects of the needle size and the flow behavior on the flow rate in the scaffold fabrication process. The developed model was also applied to determine the dispensing conditions for fabricating 3D scaffolds from a 50% chitosan-hydroxyapatite colloidal gel. As an example, a scaffold fabricated with a well-controlled internal structure of diameters of 610±43μm and pore sizes of 850±75μm in the horizontal plane and of 430±50μm in the vertical direction is presented in this paper to illustrate the promise of the developed model as applied to the 3D scaffold fabrication.
publisherThe American Society of Mechanical Engineers (ASME)
titleModeling of the Flow Rate in the Dispensing-Based Process for Fabricating Tissue Scaffolds
typeJournal Paper
journal volume130
journal issue2
journal titleJournal of Manufacturing Science and Engineering
identifier doi10.1115/1.2789725
journal fristpage21003
identifier eissn1528-8935
keywordsFlow (Dynamics)
keywordsManufacturing
keywordsBiomaterials
keywordsneedles
keywordsModeling
keywordsTemperature
keywordsTissue scaffolds AND Engineering simulation
treeJournal of Manufacturing Science and Engineering:;2008:;volume( 130 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record