Show simple item record

contributor authorS. C. Geckler
contributor authorP. E. Sojka
date accessioned2017-05-09T00:28:26Z
date available2017-05-09T00:28:26Z
date copyrightJune, 2008
date issued2008
identifier issn0098-2202
identifier otherJFEGA4-27318#061303_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/138224
description abstractThe effervescent atomization of viscoelastic liquids is reported. A total of 23 fluids, formulated from a 60wt% glycerine/40wt% water solvent to which were added varying concentrations (0.001–0.5wt%) of poly(ethylene oxide) polymers whose molecular weights ranged from 12,000 to 900,000, were sprayed through a conventional effervescent atomizer. Mean drop sizes were measured using a forward light scattering instrument. The drop size (D32) data show the expected decrease with an increase in air-liquid ratio by mass (ALR), the expected increase with an increase in polymer concentration, plus an increase with an increase in polymer molecular weight for most cases. However, no significant change in D32 was observed for polymer solutions whose molecular weights ranged from 12,000 to 35,000, suggesting the presence of a critical molecular weight below which spray performance is unaltered. This argues for two different factors controlling drop size: Polymer molecular weight is most influential at the highest polymer concentrations while polymer concentration is most influential at the lowest polymer concentrations. Analysis of the spray formation process was carried out using a ligament formation model previously developed for the effervescent atomization of Newtonian liquids coupled with a linear stability model for the breakup of viscoelastic liquid jets. The jet breakup model assumes that an unrelaxed axial tension exists within the fluid. A comparison of model predictions and experimental data indicates that the model predicts the observed dependencies of mean drop size on ALR, polymer concentration, and polymer molecular weight. Quantitative agreement is within 10–50% of experimental values in all cases. Finally, a shortcoming of the model is noted and a means of avoiding this limitation reported.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffervescent Atomization of Viscoelastic Liquids: Experiment and Modeling
typeJournal Paper
journal volume130
journal issue6
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.2917430
journal fristpage61303
identifier eissn1528-901X
keywordsFluids
keywordsDrops
keywordsPolymers
keywordsSprays
keywordsMolecular weight
keywordsWater
keywordsStability AND Tension
treeJournal of Fluids Engineering:;2008:;volume( 130 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record