Show simple item record

contributor authorDong Zhao
contributor authorHideyuki Sakoda
contributor authorW. Gregory Sawyer
contributor authorScott A. Banks
contributor authorBenjamin J. Fregly
date accessioned2017-05-09T00:27:04Z
date available2017-05-09T00:27:04Z
date copyrightFebruary, 2008
date issued2008
identifier issn0148-0731
identifier otherJBENDY-26789#011004_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/137507
description abstractWear of ultrahigh molecular weight polyethylene remains a primary factor limiting the longevity of total knee replacements (TKRs). However, wear testing on a simulator machine is time consuming and expensive, making it impractical for iterative design purposes. The objectives of this paper were first, to evaluate whether a computational model using a wear factor consistent with the TKR material pair can predict accurate TKR damage measured in a simulator machine, and second, to investigate how choice of surface evolution method (fixed or variable step) and material model (linear or nonlinear) affect the prediction. An iterative computational damage model was constructed for a commercial knee implant in an AMTI simulator machine. The damage model combined a dynamic contact model with a surface evolution model to predict how wear plus creep progressively alter tibial insert geometry over multiple simulations. The computational framework was validated by predicting wear in a cylinder-on-plate system for which an analytical solution was derived. The implant damage model was evaluated for 5 million cycles of simulated gait using damage measurements made on the same implant in an AMTI machine. Using a pin-on-plate wear factor for the same material pair as the implant, the model predicted tibial insert wear volume to within 2% error and damage depths and areas to within 18% and 10% error, respectively. Choice of material model had little influence, while inclusion of surface evolution affected damage depth and area but not wear volume predictions. Surface evolution method was important only during the initial cycles, where variable step was needed to capture rapid geometry changes due to the creep. Overall, our results indicate that accurate TKR damage predictions can be made with a computational model using a constant wear factor obtained from pin-on-plate tests for the same material pair, and furthermore, that surface evolution method matters only during the initial “break in” period of the simulation.
publisherThe American Society of Mechanical Engineers (ASME)
titlePredicting Knee Replacement Damage in a Simulator Machine Using a Computational Model With a Consistent Wear Factor
typeJournal Paper
journal volume130
journal issue1
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2838030
journal fristpage11004
identifier eissn1528-8951
keywordsWear
keywordsMachinery
keywordsCycles
keywordsKnee joint prostheses
keywordsCylinders
keywordsGeometry AND Creep
treeJournal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record