contributor authorT. J. Dudzinski
contributor authorR. C. Johnson
contributor authorL. N. Krause
date accessioned2017-05-09T00:22:47Z
date available2017-05-09T00:22:47Z
date copyrightMarch, 1969
date issued1969
identifier issn0098-2202
identifier otherJFEGA4-27327#116_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/135267
description abstractThe effects on venturi meter efficiency and discharge coefficient of a radial, outward step at the transition from throat to diffuser are reported over a Reynolds number range of 1 × 104 to 5 × 105 and over a Mach number range of 0.2 to 1.0. Step size was varied from 0 to 12.5 percent of the throat radius. The efficiency increases with increasing Reynolds number, decreases with increasing Mach number, and decreases as step size increases beyond 2 percent. The discharge coefficient was independent of Mach number and step size, and also of back-pressure variation at critical flow.
publisherThe American Society of Mechanical Engineers (ASME)
titleVenturi Meter With Separable Diffuser
typeJournal Paper
journal volume91
journal issue1
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.3571012
journal fristpage116
journal lastpage120
identifier eissn1528-901X
keywordsDiffusers
keywordsVenturi tubes
keywordsMach number
keywordsReynolds number
keywordsDischarge coefficient
keywordsPressure AND Flow (Dynamics)