description abstractThe hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)—the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional model geometry of a straight conduit with sudden expansion distal the valves, including the valve housing and detailed hinge geometry. An aortic flow waveform (60 beats/min, cardiac output 4 l∕min) was applied at the inlet. The FSI formulation utilized a fully implicit coupling procedure using a separate solver for the fluid problem (FLUENT ) and for the structural problem. Valve leaflet excursion and pressure differences were calculated, as well as shear stress on the leaflets and accumulated shear stress on particles released during both forward and backward flow phases through the open and closed valve, respectively. In contrast to the SJM, the ATS valve opened to less than maximal opening angle. Nevertheless, maximal and mean pressure gradients and velocity patterns through the valve orifices were comparable. Platelet stress accumulation during forward flow indicated that no platelets experienced a stress accumulation higher than 35 dyne×s/cm2 , the threshold for platelet activation (Hellums criterion). However, during the regurgitation flow phase, 0.81% of the platelets in the SJM valve experienced a stress accumulation higher than 35 dyne×s/cm2 , compared with 0.63% for the ATS valve. The numerical results indicate that the designs of the ATS and SJM valves, which differ mostly in their hinge mechanism, lead to different potential for platelet activation, especially during the regurgitation phase. This numerical methodology can be used to assess the effects of design parameters on the flow induced thrombogenic potential of blood recirculating devices.
publisherThe American Society of Mechanical Engineers (ASME)
titleComparison of the Hemodynamic and Thrombogenic Performance of Two Bileaflet Mechanical Heart Valves Using a CFD/FSI Model
typeJournal Paper
journal volume129
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2746378
journal fristpage558
journal lastpage565
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsStress
keywordsShear (Mechanics)
keywordsComputational fluid dynamics
keywordsValves
keywordsHemodynamics
keywordsFluid structure interaction
keywordsPlatelets AND Heart valve prostheses
treeJournal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 004