Show simple item record

contributor authorJason T. Shearn
contributor authorNatalia Juncosa-Melvin
contributor authorGregory P. Boivin
contributor authorMarc T. Galloway
contributor authorWendy Goodwin
contributor authorCynthia Gooch
contributor authorMichael G. Dunn
contributor authorDavid L. Butler
date accessioned2017-05-09T00:22:40Z
date available2017-05-09T00:22:40Z
date copyrightDecember, 2007
date issued2007
identifier issn0148-0731
identifier otherJBENDY-26773#848_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/135191
description abstractThe objective of this study was to determine how in vitro mechanical stimulation of tissue engineered constructs affects their stiffness and modulus in culture and tendon repair biomechanics 12weeks after surgical implantation. Using six female adult New Zealand White rabbits, autogenous tissue engineered constructs were created by seeding mesenchymal stem cells (0.1×106cells∕ml) in collagen gel (2.6mg∕ml) and combining both with a collagen sponge. Employing a novel experimental design strategy, four constructs from each animal were mechanically stimulated (one 1Hzcycle every 5min to 2.4% peak strain for 8h∕day for 2weeks) while the other four remained unstretched during the 2week culture period. At the end of incubation, three of the mechanically stimulated (S) and three of the nonstimulated (NS) constructs from each animal were assigned for in vitro mechanical testing while the other two autogenous constructs were implanted into bilateral full-thickness, full-length defects created in the central third of rabbit patellar tendons (PTs). No significant differences were found in the in vitro linear stiffnesses between the S (0.15±0.1N∕mm) and NS constructs (0.08±0.02N∕mm; mean±SD). However, in vitro mechanical stimulation significantly increased the structural and material properties of the repair tissue, including a 14% increase in maximum force (p=0.01), a 50% increase in linear stiffness (p=0.001), and 23–41% increases in maximum stress and modulus (p=0.01). The S repairs achieved 65%, 80%, 60%, and 40% of normal central PT maximum force, linear stiffness, maximum stress, and linear modulus, respectively. The results for the S constructs exceed values obtained previously by our group using the same animal and defect model, and to our knowledge, this is the first study to show the benefits of in vitro mechanical stimulation on tendon repair biomechanics. In addition, the linear stiffnesses for the construct and repair were positively correlated (r=0.56) as were their linear moduli (r=0.68). Such in vitro predictors of in vivo outcome hold the potential to speed the development of tissue engineered products by reducing the time and costs of in vivo studies.
publisherThe American Society of Mechanical Engineers (ASME)
titleMechanical Stimulation of Tendon Tissue Engineered Constructs: Effects on Construct Stiffness, Repair Biomechanics, and Their Correlation
typeJournal Paper
journal volume129
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2800769
journal fristpage848
journal lastpage854
identifier eissn1528-8951
keywordsForce
keywordsMaintenance
keywordsBiomechanics
keywordsBiological tissues
keywordsStiffness
keywordsTendons
keywordsSurgery
keywordsStress
keywordsMaterials properties AND Thickness
treeJournal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record