Show simple item record

contributor authorGregory S. Lewis
contributor authorStephen J. Piazza
contributor authorH. J. Sommer
date accessioned2017-05-09T00:18:55Z
date available2017-05-09T00:18:55Z
date copyrightAugust, 2006
date issued2006
identifier issn0148-0731
identifier otherJBENDY-26601#596_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/133183
description abstractThe locations of the joint axes of the ankle complex vary considerably between subjects, yet no noninvasive method with demonstrated accuracy exists for locating these axes. The moments of muscle and ground reaction forces about the joint axes are dependent on axis locations, making knowledge of these locations critical to accurate musculoskeletal modeling of the foot and ankle. The accuracy of a computational optimization method that fits a two-revolute model to measured motion was assessed using computer-generated data, a two-revolute mechanical linkage, and three lower-leg cadaver specimens. Motions were applied to cadaver specimens under axial load while bone-mounted markers attached to the tibia, talus, and calcaneus were tracked using a video-based motion analysis system. Estimates of the talocrural and subtalar axis locations were computed from motions of the calcaneus relative to the tibia using the optimization method. These axes were compared to mean helical axes computed directly from tibia, talus, and calcaneus motions. The optimization method performed well when the motions were computer-generated or measured in the mechanical linkage, with angular differences between optimization and mean helical axes ranging from 1deg to 5deg. In the cadaver specimens, however, these differences exceeded 20deg. Optimization methods that locate the anatomical joint axes of the ankle complex by fitting two revolute joints to measured tibia-calcaneus motions may be limited because of problems arising from non-revolute behavior.
publisherThe American Society of Mechanical Engineers (ASME)
titleIn Vitro Assessment of a Motion-Based Optimization Method for Locating the Talocrural and Subtalar Joint Axes
typeJournal Paper
journal volume128
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2205866
journal fristpage596
journal lastpage603
identifier eissn1528-8951
keywordsMotion
keywordsLinkages
keywordsOptimization AND Computers
treeJournal of Biomechanical Engineering:;2006:;volume( 128 ):;issue: 004
contenttypeFulltext