Show simple item record

contributor authorLi Cao
contributor authorInchan Youn
contributor authorFarshid Guilak
contributor authorLori A Setton
date accessioned2017-05-09T00:18:52Z
date available2017-05-09T00:18:52Z
date copyrightOctober, 2006
date issued2006
identifier issn0148-0731
identifier otherJBENDY-26616#766_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/133165
description abstractThe mechanical properties of articular cartilage serve as important measures of tissue function or degeneration, and are known to change significantly with osteoarthritis. Interest in small animal and mouse models of osteoarthritis has increased as studies reveal the importance of genetic background in determining predisposition to osteoarthritis. While indentation testing provides a method of determining cartilage mechanical properties in situ, it has been of limited value in studying mouse joints due to the relatively small size of the joint and thickness of the cartilage layer. In this study, we developed a micro-indentation testing system to determine the compressive and biphasic mechanical properties of cartilage in the small joints of the mouse. A nonlinear optimization program employing a genetic algorithm for parameter estimation, combined with a biphasic finite element model of the micro-indentation test, was developed to obtain the biphasic, compressive material properties of articular cartilage. The creep response and material properties of lateral tibial plateau cartilage were obtained for wild-type mouse knee joints, by the micro-indentation testing and optimization algorithm. The newly developed genetic algorithm was found to be efficient and accurate when used with the finite element simulations for nonlinear optimization to the experimental creep data. The biphasic mechanical properties of mouse cartilage in compression (average values: Young’s modulus, 2.0MPa; Poisson’s ratio, 0.20; and hydraulic permeability, 1.1×10−16m4∕N‐s) were found to be of similar orders of magnitude as previous findings for other animal cartilages, including human, bovine, rat, and rabbit and demonstrate the utility of the new test methods. This study provides the first available data for biphasic compressive properties in mouse cartilage and suggests a promising method for detecting altered cartilage mechanics in small animal models of osteoarthritis.
publisherThe American Society of Mechanical Engineers (ASME)
titleCompressive Properties of Mouse Articular Cartilage Determined in a Novel Micro-Indentation Test Method and Biphasic Finite Element Model
typeJournal Paper
journal volume128
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2246237
journal fristpage766
journal lastpage771
identifier eissn1528-8951
keywordsOptimization
keywordsFinite element model
keywordsCartilage
keywordsTesting AND Creep
treeJournal of Biomechanical Engineering:;2006:;volume( 128 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record