Show simple item record

contributor authorAlexander I. Veress
contributor authorGrant T. Gullberg
contributor authorJeffrey A. Weiss
date accessioned2017-05-09T00:15:11Z
date available2017-05-09T00:15:11Z
date copyrightDecember, 2005
date issued2005
identifier issn0148-0731
identifier otherJBENDY-26573#1195_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/131297
description abstractThe assessment of regional heart wall motion (local strain) can localize ischemic myocardial disease, evaluate myocardial viability, and identify impaired cardiac function due to hypertrophic or dilated cardiomyopathies. The objectives of this research were to develop and validate a technique known as hyperelastic warping for the measurement of local strains in the left ventricle from clinical cine-magnetic resonance imaging (MRI) image datasets. The technique uses differences in image intensities between template (reference) and target (loaded) image datasets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target image. To validate the technique, MRI image datasets representing two deformation states of a left ventricle were created such that the deformation map between the states represented in the images was known. A beginning diastolic cine-MRI image dataset from a normal human subject was defined as the template. A second image dataset (target) was created by mapping the template image using the deformation results obtained from a forward FE model of diastolic filling. Fiber stretch and strain predictions from hyperelastic warping showed good agreement with those of the forward solution (R2=0.67 stretch, R2=0.76 circumferential strain, R2=0.75 radial strain, and R2=0.70 in-plane shear). The technique had low sensitivity to changes in material parameters (ΔR2=−0.023 fiber stretch, ΔR2=−0.020 circumferential strain, ΔR2=−0.005 radial strain, and ΔR2=0.0125 shear strain with little or no change in rms error), with the exception of changes in bulk modulus of the material. The use of an isotropic hyperelastic constitutive model in the warping analyses degraded the predictions of fiber stretch. Results were unaffected by simulated noise down to a signal-to-noise ratio (SNR) of 4.0 (ΔR2=−0.032 fiber stretch, ΔR2=−0.023 circumferential strain, ΔR2=−0.04 radial strain, and ΔR2=0.0211 shear strain with little or no increase in rms error). This study demonstrates that warping in conjunction with cine-MRI imaging can be used to determine local ventricular strains during diastole.
publisherThe American Society of Mechanical Engineers (ASME)
titleMeasurement of Strain in the Left Ventricle during Diastole with cine-MRI and Deformable Image Registration
typeJournal Paper
journal volume127
journal issue7
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2073677
journal fristpage1195
journal lastpage1207
identifier eissn1528-8951
keywordsWarping
keywordsDeformation
keywordsFibers
keywordsConstitutive equations
keywordsMagnetic resonance imaging
keywordsFinite element model
keywordsErrors AND Noise (Sound)
treeJournal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 007